“Basic Settings”
To access the “Basic settings” menu, press and
hold the basic settings button
4
.
Briefly press the basic settings button
4
to select
the individual menu items.
Press the minus button
5
or the plus button
11
to
select the setting within the menu items.
To exit the “Basic settings” menu, press the meas-
urement button
2
.
With exception of the “Permanent laser beam” set-
ting, all basic settings are retained when switching
off.
Continuous Laser Beam
Do not point the laser beam at persons or ani-
mals and do not look into the laser beam your-
self, not even from a large distance.
In this setting, the laser beam also remains
switched on between measurements; for measur-
ing, it is only required to press the measuring but-
ton
2
once.
Measuring Functions
Simple Length Measurement
For length measurements, press button
12
until the
“length measurement” indication appears on the
display.
To switch the laser on and for
measuring, briefly press the meas-
uring button
2
once each time.
The measured value is displayed in
the result line
c
.
For several subsequent length measurements, the
last measured results are displayed in the meas-
ured-value lines
a
.
Area Measurement
For area/surface measurements, press button
12
until the indicator for area measurement ap-
pears on the display.
Afterwards, measure the length and the width, one
after another, in the same manner as a length
measurement. The laser beam remains switched
on between both measurements.
Upon completion of the second
measurement, the surface is auto-
matically calculated and displayed
in the result line
c
. The individual
measured values are displayed in
the measured-value lines
a
.
Volume Measurement
For volume measurements, press button
12
until
the indicator for volume measurement
appears
on the display.
Afterwards, measure the length, width and the
height, one after another, in the same manner as
for a length measurement. The laser beam remains
switched on between all three measurements.
Upon completion of the third
measurement, the volume is auto-
matically calculated and displayed
in the result line
c
. The individual
measured values are displayed in
the measured-value lines
a
.
Values above 999999 m
3
cannot be indicated;
“ERROR”
appears on the display. Divide the vol-
ume to be measured into individual measurements;
their values can then be calculated separately and
then summarized.
Continuous Measurement (Tracking) / Mini-
mum/Maximum Measurement (see figure B)
For continuous measurements, the measuring tool
can be moved relative to the target, whereby the
measuring value is updated approx. every
0.5 seconds. In this manner, as an example, you
can move a certain distance away from a wall, while
the actual distance can always be read.
Basic Settings
Tone Signals
On
Off
Display Illumination
On
Off
Auto on/off
Digital vial
On
Off
Display rotation
On
Off
Permanent laser beam
On
Off
Unit of measure, dis-
tance (depending on
country version)
m, ft, inch, ...
Unit of measure, angle
°
, %, mm/m