52
T419S Indicator Service Manual
6
ADMIN Menu
ENQ
Choose this to send data when the indicator receives the
configured enquire code from an external device. The
information will be sent through the selected binding using the
associated attributes. See
.
SMA
Choose this to send and receive data when using the SMA
(Scale Manufacturers Association) protocol. See
. The information will be sent through the
bound port using attributes that are predefined by the SMA
protocol.
B-Cast
Choose this to send data continuously through the selected
binding using the associated attributes. Typical use is for
remote scoreboards, displays and the Analog output option
if installed. See
ENQ & B-Cast commands on page 65
.
PLC
Choose this to send and receive data to/from a PLC network.
A binding of Enet x (1 through 10) is required. The attributes
are established using the PLC menu described later in this
manual. See
PLC Configuration information on page 67
FTP
Choose this to send data via FTP. A binding of Enet x (1
through 10) is required. The Rate attribute determines the
time (in minutes) between attempted FTP updates. A second
Protocol is required to complete the FTP setup. This
additional protocol requires a Type x = PRINT, Bind x = File
and Attributes x will need a Print Format. Also, set File Path
= FTP and define the File Mode (File naming convention) in
the File menu described later in this manual.
RD
Choose this to use the indicator as a remote display. When
set as a remote display, the indicator will only function as a
remote display for the connected primary indicator which is
connected to the weighing platform.
This requires a special
application
.
NCI
Choose this to use the NCI communication protocol. See
Report
Choose this for reports using footers and headers.
This
requires a special application
.
BSQ
Choose this when using a BSQ base.
intPrt
This stands for input interpreter. Choose this when using
macros.
This can only be configured via Ztools.
See the
warning below.
App
Application dependent, used for data exchange port selection.
Hid
Use to configure an input device type, i.e. bar code scanner,
RFID reader, etc., for serial, ethernet or USB interface.
ZB210
Choose this when using a ZB210 digital junction box.
WARNING: If using Input Interpreter, do NOT change to another TYPE from the
front panel or Input Interpreter will not be available without reconfiguring from
Ztools.
Summary of Contents for T419S
Page 2: ...BTEK_T419S_s_en_501788 book 2019 B TEK All rights reserved ...
Page 118: ...118 T419S Indicator Service Manual ...
Page 130: ...130 T419S Indicator Service Manual ...
Page 134: ...134 T419S Indicator Service Manual Last 28 Temp 28 ...
Page 135: ......
Page 136: ...B TEK Scale LLC 1510 Metric Ave SW Canton OH 44706 3088 ...