80
T419S Indicator Service Manual
8
Option cards
Figure 8.9 802.11g wireless communication antenna and connection point
8.8 Internal 120 VAC relay card
The AC relay converts three logic level outputs into AC solid state relays internal to the
indicator. The AC relay card is shown in
Figure 8.10 AC relay option card
8.8.1 Specifications
Output Channels (all positions)
Switched AC
Maximum output voltage
120V rms
Minimum output voltage
20V rms
Maximum output current
1A rms
Minimum output current
5mA rms
Maximum off-state voltage
400V peak
Maximum off-state leakage current
1mA rms
Maximum power dissipation
1.6 W