T419S Indicator Service Manual
47
6.3
System menu
Auto
Choices under this are
on
,
PwrUp
and
Off
. Choose
On
(the default
setting) and the indicator will update anytime it receives an update via
Zcom. Choose
PwrUp
to have the indicator auto-update on powerup if an
update is available. Choose
Off
to turn auto-update off.
6.3.10 Password
Use this to change the password for the
Admin
,
Diag
and
Calib
menus.
6.3.11 Z-Lock
This stands for zero lock. Use this to enable and configure the zero lock feature during
an automated weighing process. When enabled, if the scale does not achieve a stable,
gross zero condition some time within X minutes (the time you configure), then the
indicator locks up and displays a message in three, one second displays:
Z-Lock
Press Zero
. The operator must press
ZERO/ENTER
to unlock the indicator.
Enable
Off
or
On
.
Off
is the default.
Time
Use this to set the time value, in minutes, for this function. 60 minutes is
the default.
6.3.12 Beeper
Use this to enable or disable the beeper sound when you press keys.
on
is the default.
6.3.13 Num Scl
Use this to key in the number of scales attached to the scale (4 max). To access
settings for a scale use the
SCALE
key to display the proper scale number. Default is 1.
This completes the System menu.
If
Auto
=
Off
, the only way to update the indicator is to use the
Manual
update and
select
Yes
.
If the ADMIN password is changed, be sure to keep a record of it available for service
personnel or they may not be able to perform required maintenance when necessary.
Summary of Contents for T419S
Page 2: ...BTEK_T419S_s_en_501788 book 2019 B TEK All rights reserved ...
Page 118: ...118 T419S Indicator Service Manual ...
Page 130: ...130 T419S Indicator Service Manual ...
Page 134: ...134 T419S Indicator Service Manual Last 28 Temp 28 ...
Page 135: ......
Page 136: ...B TEK Scale LLC 1510 Metric Ave SW Canton OH 44706 3088 ...