![BTEK T419S Service Manual Download Page 88](http://html.mh-extra.com/html/btek/t419s/t419s_service-manual_2825011088.webp)
88
T419S Indicator Service Manual
8
Option cards
8.15 DC output, 4 relays (3-60VDC) card
This card allows you control up to four 3-60VDC output solid state relays. Each output
is rated for up to 2 Amps with internal fuses.
Figure 8.16 Wiring example
The use of Ztools is required to configure the DC Output option card.
TB1
Pin
Function
1
SP1-
2
SP1+
3
SP2-
4
SP2+
5
SP3-
6
SP3+
7
SP4-
8
SP4+
See
Pin 1
AWT25-501894 PCBA
(K)
TB1
TB1
+
= 2 Amps MAX
+
-
-
Ground
Load
-
+
External
DC Power Source
3-60 VDC
for output control