![BTEK T419S Service Manual Download Page 39](http://html.mh-extra.com/html/btek/t419s/t419s_service-manual_2825011039.webp)
T419S Indicator Service Manual
39
6.2
Scale menu
Option
Pick this mode if you are using the analog scale option card.
Protcl
Pick this mode if you are using the BSQ base connected to a
serial port or if you are using a ZB210. The ZB210 must be
configured fully through Ztools. For more information on the
ZB210 refer to the
ZB210 Installation/Service manual
, PN
AWT35-501806.
Bind
This option appears in two different forms depending on which Mode you
pick. If you pick
Disable
or
Onboard
in the Mode menu, the
Bind
menu
does not appear.
If you choose
Option
, this selection requires a bus and card number. Up
to four option cards can be installed.
If you choose
Protcl
, you must choose a binding with a protocol selection.
There are 20 available protocols and the protocol number selected must
be matched with a properly configured protocol shown in
.
Summary of Contents for T419S
Page 2: ...BTEK_T419S_s_en_501788 book 2019 B TEK All rights reserved ...
Page 118: ...118 T419S Indicator Service Manual ...
Page 130: ...130 T419S Indicator Service Manual ...
Page 134: ...134 T419S Indicator Service Manual Last 28 Temp 28 ...
Page 135: ......
Page 136: ...B TEK Scale LLC 1510 Metric Ave SW Canton OH 44706 3088 ...