![BTEK T419S Service Manual Download Page 58](http://html.mh-extra.com/html/btek/t419s/t419s_service-manual_2825011058.webp)
58
T419S Indicator Service Manual
6
ADMIN Menu
Depending on the choice made for
Type
, a
Config
menu may appear. Below are the
Config and/or Calibration menus that will appear for the installed card.
If USB-D or RS485/20ma card is installed:
Config
Baud
Select from the list of baud rates.
D-Bits
Select 7 or 8.
Parity
Select none, odd or even.
S-Bits
Select 1 or 2 stop bits.
Md-485
Select Full or Half duplexing.
If DeviceNet card is installed:
Config
Node
0-63
Baud
Select from 125K, 250K or 500K.
Rate
Select 1, 2, 5, 10, or 20.
If Profibus card is installed:
Config
Node
0-126
Rate
Select 1, 2, 5, 10, or 20.