T419S Indicator Service Manual
45
6.3
System menu
Lst Smp
Activate this to see the Last sample size value. The last sample size
parameter represents the number of pieces used during the last sample
routine to determine the current average piece weight. Only one last
sample size parameter is maintained for all enabled scales.
ROC
Rate of Change
USRMSG
User message (Macros only)
VAR
User variable
6.3.5 Tare
Use this item to set the type of tare entry and the tare autoclear functions.
PushBt
This stands for pushbutton tare. Enable this to use the
TARE
key to tare
weight from the scale.
on
is the default value.
Enter
This stands for keypad entry tare. Enable this and you can key in a tare
value and press
TARE
to activate it during normal weighing mode.
Off
is
the default.
Preset
This stands for preset tare. Preset tare values are entered in a password
protected menu and can be recalled, if this parameter is enabled.
Off
is the
default value.
TareCl
This stands for automatic tare clear. Enable this to automatically clear a
tare after a weighment when the weight falls into the gross zero band.
Off
is the default value.
HiRes
This stands for high resolution tare. If On, the indicator does not round the
tare value to the current division size. Choose
On
to enable high resolution
tare or
Off
to disable high resolution tare. Default is
Off
.
6.3.6 Config
Use this to print out the configuration data through one of the ports or reset the
configuration or calibration to factory defaults. Follow these steps:
Use this to print the indicator configuration information. You pick the port
to use for printing in the following steps. See the extensive list in Chapter
Choices are
Port 1
,
Port 2
,
Port 3
and
USB
(text file).
Pushbutton and keyboard entry tare can both be set to on simultaneously. The
TARE
key must be enabled in the
Button
menu.
If USB is selected, a USB flash drive must be installed to create the text file of the
indicator configuration.
Summary of Contents for T419S
Page 2: ...BTEK_T419S_s_en_501788 book 2019 B TEK All rights reserved ...
Page 118: ...118 T419S Indicator Service Manual ...
Page 130: ...130 T419S Indicator Service Manual ...
Page 134: ...134 T419S Indicator Service Manual Last 28 Temp 28 ...
Page 135: ......