4.8 The Help System
QUANTAX EDS
47
It will not always be possible
to get a perfect fit, especially with the
first frame (top left) as the image may
be affected by stage backlash.
Once the user has determined the best fit after
adjustment, confirm it by pressing the
button. The
Current values
will then be updated.
4.7.5
WDS
For details refer to the QUANTAX WDS User Manual
and the XSense Reference Manual.
4.7.6
Microscope
Microscope data is also
controlled via
MICROSCOPE
CONFIGURATION
dialog. To enable
the microscope data transfer, the
Communication active
checkbox
must be ticked.
The microscope communication settings are fixed
during installation of the QUANTAX system. Image
channel names are set to “Ch 1” and “Ch 2” by
default. These names can be changed here to EM-
specific channels (e.g., SE, BSE, HAADF,…). It is not
advised for users to modify the other settings in this
section unless explicitly advised by Bruker Service
personnel.
4.7.7
Stage
The limits must not be
changed without informing Bruker
Service personnel.
To verify the stage limits, select the
tab.
The stage limits for the SEM are set during
installation of the QUANTAX system.
4.8
The Help System
Help system.
ESPRIT features a multi-level help
system. Descriptions are provided for all major
control elements. Dialog boxes pop up, if manual
interaction is required. Warnings to prevent
performing undesired actions are displayed to the
user.
Program help.
The comprehensive user manual can
be accessed from the program window using the
icon.
Context sensitive help.
The mouse cursor is
context sensitive. When moving the mouse over
objects, e.g. buttons and labels containing short
explanations are displayed.
Assistants.
Interactive assistants provide step-by-
step instructions for common analytical tasks.
Summary of Contents for QUANTAX EDS
Page 1: ...QUANTAX EDS Energy dispersive X ray spectrometer for electron microscopy User Manual ...
Page 6: ......
Page 8: ...User Manual 2 Safety Information 8 ...
Page 12: ......
Page 14: ...User Manual 3 The QUANTAX EDS System 14 ...
Page 22: ......
Page 24: ......
Page 48: ......
Page 50: ...User Manual 5 Step by Step Guides 50 ...
Page 54: ...User Manual 5 Step by Step Guides 54 Fig 5 2 1 Spectrometer calibration ...
Page 56: ...User Manual 5 Step by Step Guides 56 Fig 5 3 1 Image capture ...
Page 58: ...User Manual 5 Step by Step Guides 58 Fig 5 4 1 Image extension ...
Page 60: ...User Manual 5 Step by Step Guides 60 Fig 5 5 1 Image drift correction ...
Page 62: ...User Manual 5 Step by Step Guides 62 Fig 5 6 1 Image processing ...
Page 67: ...5 8 Using the Spectrum Chart QUANTAX EDS 67 Fig 5 8 1 Features in the spectrum chart ...
Page 72: ...User Manual 5 Step by Step Guides 72 Fig 5 10 2 Beam current setting ...
Page 75: ...5 11 Standards Library QUANTAX EDS 75 Fig 5 11 2 Quantification dialog ...
Page 97: ...5 14 Object Analysis QUANTAX EDS 97 Fig 5 14 1 Object analysis ...
Page 108: ...User Manual 5 Step by Step Guides 108 Fig 5 19 1 Map processing ...
Page 111: ...5 20 Phase Analysis QUANTAX EDS 111 Fig 5 20 1 Performing phase analysis ...
Page 113: ...5 21 Creating a Report QUANTAX EDS 113 Fig 5 21 1 Creating a report ...
Page 116: ......