User Manual
4 The ESPRIT 2 Software
32
Use the downward-facing arrow in the left bottom
corner of a configurator ( or
icon, depending
on the display mode)
to access the corresponding
configuration dialog.
4.5.1
Sample Configuration
Fig. 4.5-3 Sample configurator
Fig. 4.5-4 Sample configurator select entry
menu
Fig. 4.5-5 Sample properties dialog
The
Sample configurator
is used to display and
manage information about the sample. The
information displayed is divided into the following
parameters:
Sample type
Coating type
Company
Batch
Sample
The parameter to be displayed can be set by the user
by clicking with the right mouse key on the displayed
value in the configurator and selecting the desired
parameter in the
Select entry
menu.
When clicking on the
icon in the bottom left
corner of the
Sample
configurator, the
SAMPLE
PROPERTIES
dialog pops up. Before measurement,
general properties of the sample can be entered in
this dialog. All subsequently collected data
(spectrum, image, line scan, map) will contain these
parameters. Default input parameters are name and
description. Additional user-defined data can be
added clicking the
icon.
Sample coating.
If the sample is coated to enhance
electrical conductivity, this can be entered under
Sample coating
.
None.
Select this option, if the sample is not coated.
Coating with.
Select this option, if the sample is coated.
Select the element of the coating material in the periodic
table which pops up after selecting this option. The
selected element will be considered for the peak
deconvolution algorithm but will not be quantified. The
display changes to
Coating with “Element name”
.
Coating calibration
. Select this option, if the sample is
coated and a coating correction data file (.ccc) is
available. Open the *.ccc file in the popup dialog.
4.5.2
Standards
Configuration
The
Standards configurator
is available, if a
standard-based EDS quantification license is
Summary of Contents for QUANTAX EDS
Page 1: ...QUANTAX EDS Energy dispersive X ray spectrometer for electron microscopy User Manual ...
Page 6: ......
Page 8: ...User Manual 2 Safety Information 8 ...
Page 12: ......
Page 14: ...User Manual 3 The QUANTAX EDS System 14 ...
Page 22: ......
Page 24: ......
Page 48: ......
Page 50: ...User Manual 5 Step by Step Guides 50 ...
Page 54: ...User Manual 5 Step by Step Guides 54 Fig 5 2 1 Spectrometer calibration ...
Page 56: ...User Manual 5 Step by Step Guides 56 Fig 5 3 1 Image capture ...
Page 58: ...User Manual 5 Step by Step Guides 58 Fig 5 4 1 Image extension ...
Page 60: ...User Manual 5 Step by Step Guides 60 Fig 5 5 1 Image drift correction ...
Page 62: ...User Manual 5 Step by Step Guides 62 Fig 5 6 1 Image processing ...
Page 67: ...5 8 Using the Spectrum Chart QUANTAX EDS 67 Fig 5 8 1 Features in the spectrum chart ...
Page 72: ...User Manual 5 Step by Step Guides 72 Fig 5 10 2 Beam current setting ...
Page 75: ...5 11 Standards Library QUANTAX EDS 75 Fig 5 11 2 Quantification dialog ...
Page 97: ...5 14 Object Analysis QUANTAX EDS 97 Fig 5 14 1 Object analysis ...
Page 108: ...User Manual 5 Step by Step Guides 108 Fig 5 19 1 Map processing ...
Page 111: ...5 20 Phase Analysis QUANTAX EDS 111 Fig 5 20 1 Performing phase analysis ...
Page 113: ...5 21 Creating a Report QUANTAX EDS 113 Fig 5 21 1 Creating a report ...
Page 116: ......