User Manual
4 The ESPRIT 2 Software
30
To scale individual parts of the program window the
splitter (dark grey lines) between different screen
areas on the ESPRIT interface can be dragged (a
changing mouse cursor indicates availability of this
option).
Full screen / dual screen mode.
An image or a
diagram chart can be decoupled from the ESPRIT
window and switched to full screen by clicking the
full screen symbol on the upper right-hand corner
of the corresponding screen area.
If a second monitor is attached, the decoupled
window can be dragged and pulled to the second
monitor and ESPRIT can be used in extended display
mode. Revert from full screen mode by pressing the
ESC key or clicking the full screen symbol again.
Configurator bar.
The configurator bar compiles all
attached hardware parts as well as information about
the sample and standards, the scan settings and the
report and project editor. All parts of the configurator
bar are described in detail in section 4.5.
Image capture chart.
The workspaces
Objects,
Line scan, Mapping
and
Imaging
have a dedicated
chart for controlling the electron image capture.
Analysis spots, objects, scan lines, and mapping
areas can be defined on the captured image. Image
capture is controlled directly from the current
workspace. Additionally, a special window for fast
image preview is provided. For details please see
section 5.3.
One or two of the image detectors (typically the SE
and BSE detectors) can be connected to the
QUANTAX hardware and selected for image capture.
Spectrum and Result chart.
The workspaces
Spectra,
Objects, Line scan,
and
Mapping
have a
dedicated chart for displaying spectra and associated
spectrum list or results. Details are described in
section 5.8.
Icons and buttons.
A number of icons and buttons
associated to the different workspaces and display
charts are provided. All icons can be displayed in
normal or large style button mode which can be
changed by activating/ deactivating the
corresponding checkbox in the
System
/
Appearance
workspace.
Summary of Contents for QUANTAX EDS
Page 1: ...QUANTAX EDS Energy dispersive X ray spectrometer for electron microscopy User Manual ...
Page 6: ......
Page 8: ...User Manual 2 Safety Information 8 ...
Page 12: ......
Page 14: ...User Manual 3 The QUANTAX EDS System 14 ...
Page 22: ......
Page 24: ......
Page 48: ......
Page 50: ...User Manual 5 Step by Step Guides 50 ...
Page 54: ...User Manual 5 Step by Step Guides 54 Fig 5 2 1 Spectrometer calibration ...
Page 56: ...User Manual 5 Step by Step Guides 56 Fig 5 3 1 Image capture ...
Page 58: ...User Manual 5 Step by Step Guides 58 Fig 5 4 1 Image extension ...
Page 60: ...User Manual 5 Step by Step Guides 60 Fig 5 5 1 Image drift correction ...
Page 62: ...User Manual 5 Step by Step Guides 62 Fig 5 6 1 Image processing ...
Page 67: ...5 8 Using the Spectrum Chart QUANTAX EDS 67 Fig 5 8 1 Features in the spectrum chart ...
Page 72: ...User Manual 5 Step by Step Guides 72 Fig 5 10 2 Beam current setting ...
Page 75: ...5 11 Standards Library QUANTAX EDS 75 Fig 5 11 2 Quantification dialog ...
Page 97: ...5 14 Object Analysis QUANTAX EDS 97 Fig 5 14 1 Object analysis ...
Page 108: ...User Manual 5 Step by Step Guides 108 Fig 5 19 1 Map processing ...
Page 111: ...5 20 Phase Analysis QUANTAX EDS 111 Fig 5 20 1 Performing phase analysis ...
Page 113: ...5 21 Creating a Report QUANTAX EDS 113 Fig 5 21 1 Creating a report ...
Page 116: ......