4.2 User Administration
QUANTAX EDS
27
Altering user name and password
can be done at
any time from the QUANTAX communication server
(icon in the Windows
®
task bar) by clicking
in
QUANTAX user
tab.
The user data and profile are automatically copied to
the new user data structures. Backups of important
data, which are always recommended, are especially
advisable when changing user names.
Fig. 4.2-4 Access to QUANTAX server settings
The communication server port
in the top box must not be altered; it
must always match the settings on
the client workstations.
Normally there is no need to delete assigned users.
If users have to be deleted, it has to be made sure
that all user data to be retained are copied to public
volumes.
To delete a user
highlight the user name in the list
provided in the
QUANTAX user
tab of the
QUANTAX communication server. After clicking
the deletion of the user data has to be
confirmed separately. Caution, once confirmed, the
deletion cannot be revoked! If deletion of the data is
not confirmed, the data are retained invisibly; a new
user with the same name as a previously deleted will
be assigned to the idle data.
The number of assigned measure client ports
determines how many users can log in
simultaneously to the server computer. Per default
only one port is assigned, so that only one user at a
time can log in to the server computer. Even when
multiple ports are present, the hardware can only be
controlled by one user at a time.
Select a new port number in the field
Measure
client ports
and click
. Usually, the number
following the last assigned port in natural order is
adequate. Ask your system administrator for help.
The
connection setting
for a client workstation is
accessed from the ESPRIT login screen. Select the
entry
Configuration
from the
Server
dropdown list.
The
QUANTAX SERVER SETTINGS
dialog will
open.
Summary of Contents for QUANTAX EDS
Page 1: ...QUANTAX EDS Energy dispersive X ray spectrometer for electron microscopy User Manual ...
Page 6: ......
Page 8: ...User Manual 2 Safety Information 8 ...
Page 12: ......
Page 14: ...User Manual 3 The QUANTAX EDS System 14 ...
Page 22: ......
Page 24: ......
Page 48: ......
Page 50: ...User Manual 5 Step by Step Guides 50 ...
Page 54: ...User Manual 5 Step by Step Guides 54 Fig 5 2 1 Spectrometer calibration ...
Page 56: ...User Manual 5 Step by Step Guides 56 Fig 5 3 1 Image capture ...
Page 58: ...User Manual 5 Step by Step Guides 58 Fig 5 4 1 Image extension ...
Page 60: ...User Manual 5 Step by Step Guides 60 Fig 5 5 1 Image drift correction ...
Page 62: ...User Manual 5 Step by Step Guides 62 Fig 5 6 1 Image processing ...
Page 67: ...5 8 Using the Spectrum Chart QUANTAX EDS 67 Fig 5 8 1 Features in the spectrum chart ...
Page 72: ...User Manual 5 Step by Step Guides 72 Fig 5 10 2 Beam current setting ...
Page 75: ...5 11 Standards Library QUANTAX EDS 75 Fig 5 11 2 Quantification dialog ...
Page 97: ...5 14 Object Analysis QUANTAX EDS 97 Fig 5 14 1 Object analysis ...
Page 108: ...User Manual 5 Step by Step Guides 108 Fig 5 19 1 Map processing ...
Page 111: ...5 20 Phase Analysis QUANTAX EDS 111 Fig 5 20 1 Performing phase analysis ...
Page 113: ...5 21 Creating a Report QUANTAX EDS 113 Fig 5 21 1 Creating a report ...
Page 116: ......