S-7300A
10. ELECTRIC MECHANISM
173
10-5. Checking the solenoids
DANGER
Wait at least 5 minutes after turning off the power switch and disconnecting the power cord from the wall outlet
before opening the face plate of the control box. Touching areas where high voltages are present can result in
severe injury.
<Machine head>
1.
Disconnect the
solenoid connector 10P (1) from the
control box.
2.
Measure the resistance of the
solenoid connector (1)
using an ohmmeter in the x 1 range.
If the value is as shown in the table below, the connector
is normal.
Between 1 - 6
For options (*1)
Between 2 - 7
Thread trimmer solenoid:
Approx. 7.6 Ω
Between 3 - 8
Presser foot lifting solenoid
(*1)
Between 4 - 9
Thread wiper solenoid:
Approx. 10.1Ω
Between 5 - 10
Presser foot lifter switch
(*2)
(*1) Depends on which solenoid is installed
(
*2) 0 Ω when switch is ON, ∞ Ω when switch is OFF
1075D
Solenoid connector 10P
For options
Thread trimmer solenoid
Presser foot lifting solenoid
Thread wiper solenoid
Presser foot lifter switch