S-7300A
3. FUNCTION SETTINGS
33
<List of maintenance information>
Screen
Panel display
Display details
1
・
X-over sensor 1
Displays the X-over seam sensor adjustment value 1 (200 -
1400).
・
X-over sensor 2
Displays the X-over seam sensor adjustment value 2 (300 -
3400).
2
・
U-shaft REF position ADJ value
Displays the upper shaft reference position adjustment value
(60 - 100).
・
Feed REF position correction value
Displays the feed reference position correction value (-300 -
300).
3
・
Grease up counter(%)
For -[]3[] specifications, 0 - 102 is displayed.
(If the value is 100 or more, the grease up warning screen is
displayed when the power is turned on.)
For -[]0[] specifications, 0 is displayed.
・
Grease up time
For -[]3[] specifications, 4000 is displayed.
For -[]0[] specifications, 0 is displayed.
4
・
Accumulated power on time
Displays the accumulated power on time (x 1 sec).
・
Accumulated motor running time
Displays the accumulated motor running time for the sewing
machine (x 1 sec).