7. ADJUSTMENTS
S-7300A
139
7-12. Setting method for standard depression strokes
DANGER
Wait at least 5 minutes after turning off the power switch and disconnecting the power cord from the wall outlet
before opening the face plate of the control box. Touching areas where high voltages are present can result in
severe injury.
Use the following procedure to set the operating positions for the depression stroke.
1
2
3
Memorizing the maximum forward position
4
Memorizing the neutral position
5
Memorizing the maximum backward position
6
1064D
(While pressing the menu key and the home key, turn on the power
switch.)
The adjustment menu will be displayed
in the LCD panel.
1064D
(Touch "Treadle position adjustment".)
The current voltage from the treadle unit will be
displayed in the LCD panel.
(With the treadle depressed to the maximum forward position,
touch the OK button on the LCD panel.)
(With your foot released from the treadle, touch the OK button
on the LCD panel.)
The next treadle depression position will be
displayed on the LCD panel.
(With the treadle depressed to the maximum backward position,
touch the OK button on the LCD panel.)
The buzzer will sound and the LCD panel
display will show that the setting is completed.
The display will automatically
return to the adjustment menu.
Turn off the power switch to exit from the adjustment
menu.
The next treadle depression position will be
displayed on the LCD panel.
ON
OFF