CHAPTER 4 EXTENDED OPTION OUTPUT (PROGRAM)
104
BAS H series, Programmer
How to create programs
Selecting hardware on the output side
Use NPN open collector outputs.
Circuit board
It is assumed that an optionally available air valve is used.
In addition to a 24 V air valve, use a 24 VDC relay.
Circuit board
External 24V relay
Fuses are not incorporated into the output circuit. To prevent the circuit from being damaged if the output
short-circuits, it is recommended that you mount an external fuse for each circuit.
Selecting hardware on the input side
・
Use non-isolated IC inputs
・
In addition to using a contact switch or a 24 V sensor, use relays to isolate inputs.
・
Use relays for an electronic circuit with a min. application load of 5 V and 1 mA or less.
I=70 mA
COM terminal
Output terminal
+24V
Lo
ad
L
Power
supply
COM terminal
Output terminal
+24V
Lo
ad
+24V
0
+5
4.7K
Ω
Input terminal
Vcc
Sensor output
0V
Sensor output
NPN open collector
+24V
0
+5
4.7K
Ω
Input terminal
L
External
equipment
Example connection to a proximity
sensor
Circuit board
External relay
Circuit board
Summary of Contents for BAS H series
Page 8: ......
Page 9: ...Chapter 1 Read Me ...
Page 11: ...Chapter 2 Setting Up Your Programmer ...
Page 17: ...Chapter 3 Programming Patterns ...
Page 85: ...Chapter 4 Extended Option Output PROGRAM ...
Page 119: ...Chapter 5 File Manager Functions ...
Page 132: ...CHAPTER 5 FILE MANAGER FUNCTIONS 124 BAS H series Programmer ...
Page 133: ...Chapter 6 Setting Functions ...