CHAPTER 4 EXTENDED OPTION OUTPUT (PROGRAM)
100
BAS H series, Programmer
Controlling commencement of sewing by providing an input check to the
automatic start function
Add option input No. 1 to the enabling conditions in the previous section.
1. Touch
and load the programs which have already been written.
2. Display the enabling condition setting screen. Referring to the table of external input condition numbers (refer to
page 86), set enabling condition No. 1 to “enabling
when condition No. 40 (input 1 ON) is established”. Set
“disabling
when condition No. 41 (input 1 OFF) is established”.
3.
Touch
to overwrite the extended option output.
4.
Display the extended option output once more, and then touch
to apply the extended option output which
was overwritten in step 3 to the sewing machine.
5. As an additional step 7 in "Automating the commencement of sewing", confirm also that sewing commences only
when option input No. 1 is on.
By carrying out sequence control of the raising and lowering of the work clamp using the option output as shown in
the example above, you can configure the sewing machine so that material is automatically loaded before sewing.
Summary of Contents for BAS H series
Page 8: ......
Page 9: ...Chapter 1 Read Me ...
Page 11: ...Chapter 2 Setting Up Your Programmer ...
Page 17: ...Chapter 3 Programming Patterns ...
Page 85: ...Chapter 4 Extended Option Output PROGRAM ...
Page 119: ...Chapter 5 File Manager Functions ...
Page 132: ...CHAPTER 5 FILE MANAGER FUNCTIONS 124 BAS H series Programmer ...
Page 133: ...Chapter 6 Setting Functions ...