2-14
Confidential
4.1.7 Overcurrent has been detected in the device connected to the USB terminal.
The USB device connected to the USB terminal is not supported.
An USB hub is connected to the USB terminal.
4.1.8 The front cover sensor detected an open front cover.
4.1.9 Separation pad counter has exceeded the upper limit.
Pick-up roller counter has exceeded the upper limit.
Both of separation pad counter and pick-up roller counter have exceeded the
upper limit.
4.1.10 The top cover was opened when a card was set.
<User Check>
• Disconnect the device or USB hub connected to the USB terminal.
Step
Cause
Remedy
1
Main PCB failure
Replace the main PCB ASSY.
<User Check>
• Close the front cover correctly.
Step
Cause
Remedy
1
Front cover actuator coming off Reattach the front cover actuator.
2
Front cover sensor coming off
Reattach the front cover sensor.
3
Connection failure of the front
cover sensor harness
Reconnect the front cover sensor harness.
4
Front cover sensor failure
Replace the cover switch ASSY.
5
Panel PCB failure
Replace the panel unit.
6
Main PCB failure
Replace the main PCB ASSY.
<User Check>
• Replace the separation pad ASSY and reset the separation pad counter.
• Replace the pick-up roller and reset the pick-up roller counter.
Step
Cause
Remedy
1
Main PCB failure
Replace the main PCB ASSY.
<User Check>
• Close the top cover correctly.
Step
Cause
Remedy
1
Card detection actuator caught
in sections of the machine
Reattach the card detection actuator.
2
Card detection sensor failure
Replace the card detection sensor PCB ASSY.
3
Main PCB failure
Replace the main PCB ASSY.