3-19
Confidential
(4) Remove the taptite bind B M3x8 screw to remove the panel FG harness from the main PCB
ASSY.
(5) Remove the three taptite cup S M3x5 screws and taptite bind B M3x8 screw from the main
PCB ASSY.
(6) Push the gear hold plate earth wire aside and lift the main PCB ASSY. Disconnect the
panel PCB flat cable from the main PCB ASSY by releasing the connector lock. Disconnect
the main motor harness ASSY from the back side of the main PCB ASSY to remove it from
the machine.
Fig.3-13
HARNESS ROUTING: Refer to
.
Taptite cup S M3x5
Taptite bind B M3x8
Panel FG harness
Panel PCB flat cable
Main motor
harness ASSY
Main PCB ASSY
Taptite bind B M3x8
Gear hold
plate earth wire