3-18
Confidential
8.8
Main PCB ASSY
(1) Turn the machine upside down.
(2) Remove the harness protect film and two flat cable insulation film lowers from the machine.
(3) Release the two locks of the connector to disconnect the second side CIS flat cable and
first side CIS flat cable from the main PCB ASSY. Disconnect the top cover sensor
harness, card detection sensor harness, and front cover sensor harness from the main
PCB ASSY.
Fig.3-12
HARNESS ROUTING: Refer to
,
“2. Main PCB ASSY right side flat cable
and
“3. Flat cable insulation film lower attachment”
.
Note:
• Make sure that the main PCB ASSY is secured by screws when connecting/
disconnecting harnesses and flat cables.
• After disconnecting flat cables, check that each cable is not damaged at its end or
short-circuited. When connecting flat cables, do not insert them at an angle. After
insertion, check that the cables are not at an angle.
Assembling Note:
• Engage the hole on the left side of the harness protect film with the hook, and put the
section A under the main PCB ASSY as described in the illustration above.
• Check that the core is attached to the second side CIS flat cable.
Harness protect film
"A"
Flat cable insulation film lower
Second side CIS
flat cable
Flat cable
insulation film
lower
Top cover sensor
harness
Card detection
sensor harness
Front cover
sensor harness
First side CIS flat
cable
Hook
"A"
Main PCB ASSY
Main PCB ASSY
Core
Hole