Technical data • Entire device
Chap
ter 2
Te
chn
ica
l da
ta
43
Automation PC 820 User's Manual V 1.00
2.6 Device interfaces
2.6.1 Supply v24 VDC
If the APC820 is secured, it is automatically connected to the ACOPOSmulti rail supply voltage.
For information about installing the APC820, see chapter 3 "Commissioning", section 1
"Installation" on page 75.
The supply voltage is protected internally by a soldered fuse (15A, fast-acting), so that the device
cannot be damaged if there is an overload (fuse replacement necessary). The device must be
returned to B&R for repairs if the fuse is blown because of an error.
2.6.2 Ground
If the APC820 is secured, it is automatically connected to ground (ACOPOSmulti rail).
2.6.3 Monitor / Panel connection - SDL (Smart Display Link / DVI)
Monitor / Panel connection - SDL (Smart Display Link / DVI)
The following will provide an overview of the video signals
available on the monitor/panel output.
For details, see technical data for the CPU board being used.
CPU board
Video signals
5PC800.B945-00
RGB, DVI, SDL
5PC800.B945-01
RGB, DVI, SDL
5PC800.B945-02
RGB, DVI, SDL
5PC800.B945-03
RGB, DVI, SDL
5PC800.B945-04
RGB, DVI, SDL
Table 16: Monitor / Panel connection - RGB, DVI, SDL