Fig.11-9:
Quadrant error clearance
11.2.3
Project Circular Test on F-Keys
There was no retrieval for the circularity test in earlier projects. Proceed as
follows to retrieve it via an F-key:
1. The following line has to be entered into file HMI.ScreenData.XML:
<ScreenInfo Name="MtxCircularTest" ScreenType="MtxCircularTestAp‐
plication" Visible="true">
2. Find an empty F-key in the Engineering Desktop and assign it with the
function "Circularity test" (see IndraWorks documentation).
3. Assign the circularity test to an operating mode.
Open the HMI node context menu in the EDT and retrieve "Update HMI
data". Then the entry for the circularity test can be seen in the screen list.
Now the screen can also be assigned to the desired operating mode. For
this, go to the OP Panel Editor, open the operating mode editor and move
the circularity test screen from the left into the right list.
11.3
I-Remote
11.3.1
Usage
With the help of the function "I-Remote", it is now possible to access remote
machine tool control systems and to execute diagnosis or maintenance.
The I-Remote software consists of two components:
1.
The "Client" software component on the IndraMotion MTX control system,
which has to be enabled via a valid license.
2.
The "Control" software component on the remotely controlling "Service
PC".
To use the I-Remote functions on the IndraMotion MTX control, you need the
following user rights:
Application Description | Rexroth IndraMotion MTX 09VRS
Electric Drives
and Controls
| Bosch Rexroth AG 193/233
Extended Functionality