No.
Window in the
NC analyzer
Function
Possible entries
1
Variables
Displays of all CPL variables used in the pro‐
gram in tree form, structured according to the
following groups:
●
Permanent
●
Defined permanent
●
Global
●
Local
Select variables to be watched. They are
displayed in the "WATCH" window.
2
Watch
Watch variables asynchronously:List of selec‐
ted variables. The current values are displayed
in the "WATCH VALUES" window.
Delete the variables that are not be watch‐
ed any longer.
3
Watch values
Show values:Display of the variable values
from the "WATCH" window during the runtime
of the program.
Editing the values of variables (with the
exception of simple string variables) dur‐
ing the runtime of the program.
4
Program
Program window:Showing
●
The operating mode as icon, the channel
( $x) as well as the program name includ‐
ing path
●
Program code
●
The block processed at runtime
●
Breakpoints
Read-protected programs are not shown.
●
Find text
●
Set, delete, activate, deactivate
breakpoints
5
Quick Watch
Watch variables synchronously:List of selected
variables. The current values are displayed in
the "QUICK WATCH VALUES" window.
Delete the variables that are not be watch‐
ed any longer.
6
Quick Watch values
Show values synchronously:Display of the var‐
iable values from the "QUICK WATCH" window
during the runtime of the program.
Editing the values of variables (with the
exception of simple string variables) dur‐
ing the runtime of the program.
7
Stack
Select subroutine:Displays the subroutine
stacking of the selected NC program
Selection of a subroutine from the sub‐
routine structure that is currently active.
8
Output
Status display:Display of messages (MSG,
GMSG, etc.) and errors concerning the NC pro‐
gram and the NC analyzer.
Deleting the displays.
9
File
File system: Display of the file system of the
control.
Selection of a program to be shown in the
"Program" window (this is not program se‐
lection in the control).
F-Key Bars
Below the work section there are 8 F-keys, which can be operated by mouse
or via the function keys F2...F9:
●
Active keys are shown with white writing
●
Keys that are inactive, e.g. because of a configured option, are shown in
grey.
The functions of the F-keys change depending on the active window in the work
section (see the following figure).
Select a window by:
Application Description | Rexroth IndraMotion MTX 09VRS
Electric Drives
and Controls
| Bosch Rexroth AG 175/233
Extended Functionality