Seq. no.
Procedure
1
Selecting a Program
2
Start NC analyzer
3
Load configuration file (optional)
4
Channel selection (optional)
5
Navigation to the faulty program part or possibly to the subroutine in
the NC analyzer
6
Set breakpoints at supposed error locations
7
Select variables for watch
8
Start NC program
9
Watch the values of the selected variables and error analysis
10
Error clearance of the respective program parts in the editor of the
control
11
Test the program to see whether errors have been cleared.
And whether more errors exist
12
Save configuration (settings) or any subsequent NC analyzer ses‐
sions
Selecting a Program
The program selection is opened via the OP-key "Machine", the F-key <F2>.
Select the NC program to be run.
●
Only one program can be edited at a time.
●
To be able to edit a program, the file attribute of the program needs to be
configured accordingly. In the "File" window, each file is prefixed by a
symbol for the file attribute.
●
The program displayed in the NC analyzer can be edited there only if it is
active in the selected control and the configured channel.
●
If the selected program is edited in the control, all changes also become
active immediately in the NC analyzer (incl. watched variables and sub‐
routines).
WARNING
Loss of data!
●
If a different program is selected for processing, this is also loaded into
the NC analyzer at the same time. Changes in the previous program will
be lost.
●
The command "Reset channel" in the control means that breakpoints and
watched variables will be lost.
Complete Lock
In its default setting, the NC analyzer works only if the complete lock is activated
in the control, so that the axes do not move.
If it is necessary to analyze the program with moving axes, the "complete
lock" can be deactivated with a password.
Application Description | Rexroth IndraMotion MTX 09VRS
Electric Drives
and Controls
| Bosch Rexroth AG 177/233
Extended Functionality