English |
23
Bosch Power Tools
1 609 92A 3RD | (22.8.17)
Attention:
Always disconnect the drive from your operating
system first (eject drive), as failure to do so may damage the
thermal imaging camera’s internal memory.
Always keep the cover of the USB interface closed so that
dust and splashes cannot enter the housing.
Note:
Only connect the measuring tool to a PC or notebook.
The tool could be damaged if you connect it to a different de-
vice.
Note:
The micro USB interface can only be used for data
transmission – it is not suitable for charging batteries.
Post-editing the thermal images
You can post-edit the saved thermal images on your computer
if it uses a Windows operating system. To do so, download the
GTC Transfer software from the product page for the thermal
imaging camera at
www.bosch-professional.com/gtc
.
Data transmission via WiFi
The measuring tool is equipped with a WiFi module which en-
ables the saved images to be wirelessly transmitted from your
thermal imaging camera to a mobile device.
The
“Measuring Master”
application (app) is required as the
software interface for this. You can download this from the
store for your end device type:
In addition to wirelessly transmitting your images, the
“Measuring Master”
application makes it possible for you to
use an extended range of functions and facilitates post-edit-
ing and forwarding of measured data (for example via e-mail).
Information about system requirements for a WiFi connection
can be found on the Bosch website at
“www.bosch-professional.com/gtc”
.
To activate or deactivate the WiFi connection on the measur-
ing tool, call up the main menu, use the buttons to select
“WiFi”
and activate or deactivate it.
e
will appear on the dis-
play. Ensure that the WiFi interface is activated on your mo-
bile device.
The connection between the mobile device and the measur-
ing tool can be established after the Bosch application has
been started (if WiFi modules are activated). To do this, fol-
low the instructions in the
“Measuring Master”
application.
Troubleshooting – Causes and Corrective Measures
In the event of a fault, the tool will restart and can then continue to be used. If the fault persists, the following overview may help
you.
Error
Cause
Corrective Measure
Measuring tool cannot be switched on.
Battery pack or batteries
empty
Charge the battery pack or change the batteries.
Battery too warm or too cold Allow the battery to reach the correct temperature or
change it.
Measuring tool too warm or
too cold
Allow the measuring tool to reach the correct tem-
perature.
Image memory defective
Format the internal memory by deleting all images
(see “Delete all images”, page 22). If the problem
persists, send the measuring tool to an authorised
Bosch after-sales service agent.
Image memory full
If required, transfer the images to another storage
medium (e.g. computer or notebook). Then delete
the images in the internal memory.
Measuring tool is defective. Send the measuring tool to an authorised Bosch
after-sales service agent.
Measuring tool cannot be connected to a
computer.
Measuring tool not recog-
nised by computer.
Check whether the driver on your computer is up to
date. It may be necessary to have a newer operating
system version on your computer.
Micro USB connection or
micro USB cable defective
Check whether the measuring tool can be connected
to a different computer. If not, send the measuring
tool to an authorised Bosch after-sales service agent.