Focus distance
≥0.3 m
Focus
Fixed
Surface temperature measurement range
–10...+400 °C
Measuring accuracy (typical)
Surface temperature
1)
–10...+10 °C
10...100 °C
>+100 °C
±3 °C
±3 °C
±3 %
Display type
TFT
Display size
3.5"
Display resolution
320 x 240
Image format
.jpg
Images saved per saving process
1 x thermal image (screenshot)
1 x real visual image incl. temperature values (metadata)
Number of images in internal image memory (typical)
500
Integrated visual camera
Batteries (alkali-manganese)
Battery pack (lithium-ion)
4 x 1.5 V LR6 (AA) (with battery adapter)
10.8 V/12 V
Battery life
– Batteries (alkali-manganese)
– Battery pack (lithium-ion)
2.0 h
5.0 h
USB port
1.1
TrackMyTools
Bluetooth
® module power supply
– Button cell
– Battery service life, approx.
CR2450 (3 V lithium battery)
60 months
Bluetooth
®
Bluetooth
® 4.2 (Low Energy)
Max.
Bluetooth
® transmission power
3.2 mW
Frequency band
Bluetooth
®
2.402 – 2.480 GHz
Wireless connectivity
WiFi
Max. WiFi transmission power
30 mW
WiFi operating frequency range
2.400–2.483 GHz
Weight according to EPTA-Procedure 01:2014
0.54 kg
Dimensions (length x width x height)
233 x 95 x 63 mm
Degree of protection (excluding battery compartment)
IP 53
Permitted environmental conditions
– Charging temperature
– Operating temperature
2)
– Storage temperature
– Relative humidity (non-condensing)
0...+45 °C
–10...+45 °C
–20...+70 °C
20... 80 %
Recommended batteries
GBA 10,8 V
GBA 12 V
Recommended chargers
AL 11.. CV
GAL 12.. CV
Thermal imaging camera
GTC 400 C
The measuring tool can be clearly identified with the serial number
2
on the type plate.
1) at an ambient temperature of 20–23 °C and an emissivity of >0.999, measuring distance: 0.3 m, operating time: >5 min
2) limited performance at temperatures <0 °C
Technical data determined with battery from delivery scope.