background image

Fotric 320M/320F Series

User Manual

Summary of Contents for 320F Series

Page 1: ...Fotric 320M 320F Series User Manual ...

Page 2: ...n 1 1 Standard Configuration 6 Hardware 2 1 Front View 7 2 2 Rear View 8 2 3 Top View 9 2 4 Right View 10 Operation guide 3 1 battery 11 3 2 Turning on and off the thermal camera 13 3 3 Adjusting the Infrared Lens Manually 14 3 4 Copying the TF card s data to computer Via TF card reader 15 3 5 Copying the TF card s data to computer Via USB cable 15 3 6 The Laser Ranger as a pointer 16 3 7 AI progr...

Page 3: ...Image mode 41 4 8 ROI measurement tools 46 4 9 Setting Sound Alarm 60 4 10 Palette 62 4 11 Color alarm isotherms 64 SYSTEM SETTINGS 5 1 Capture mode 69 5 2 Video recording 69 5 3 Time lapse mode 70 5 4 Connection 71 5 5 Setting Temperature Range 74 5 6 Storage Save options 75 5 7 Device set 76 Image freeze interface 6 1 Favorite 89 6 2 Voice annotation 90 6 3 Text annotation 91 6 4 Tag 93 Video fr...

Page 4: ...Thermal files analysis 103 8 5 Deleting image or video file 106 8 6 Deleting multiple files 107 Thermal imager maintenance 9 1 Cleaning casing wires and other components 108 9 2 Cleaning lenses 108 9 3 Cleaning uncooled infrared focal plane detector 109 9 4 Lithium battery maintenance 110 Vocabulary Emissivity Table ...

Page 5: ...t be reported and the product must not be used after to prevent further damage The purchaser must report any defects to FOTRIC immediately otherwise this warranty will not apply If the product is proven defective in relation to materials or manufacturing after FOTRIC s inspection it is up to the user whether it is to be repaired or replaced refer to FOTRIC warranty policy provided that the product...

Page 6: ...dable electronic medium or machine without the prior written consent of FOTRIC The names and logos shown on the products herein are either registered trademarks or trademarks of FOTRIC and or its affiliates All other trademarks trade names or company names referenced herein are for identification purposes only and are the property of respective owners 1 4 Quality Assurance The quality management s...

Page 7: ...ed countries such as North Korea Iran Syria Cuba Sudan Russia etc Please do not bring this product into or used in controlled countries Any loss or liability arising from the above actions will be borne by the purchaser ...

Page 8: ...on for users Please read before using Warning This is class A product In a domestic environment this product may cause radio interference in which cause the user may be required to take adequate measures Warning Do not disassemble or do modifications to the battery of the thermal imager The battery contains safety and protection devices which if damage occurs can cause the battery to become hot or...

Page 9: ...ous chemical substances from contaminating or damaging the surface of the lens Please cover the lens with caps after use Caution Do not use the camera in temperatures higher than 50 C 122 F unless other information is specified in the user documentation or technical data High temperatures can cause damage to the camera Caution To prevent the potential risk of data loss please copy back up the data...

Page 10: ...uded lens A handheld thermal camera Lens included 2 pieces of batteries One set of USB Type C cable One set of Micro HDMI to HDMI cable TF card TF card reader Documentations Quick start user manual One set of Power adaptor Portable soft bag for specific models Portable hard case for specific models ...

Page 11: ...7 Hardware 2 1 Front View ...

Page 12: ...8 2 2 Rear View ...

Page 13: ...9 2 3 Top View ...

Page 14: ...10 2 4 Right View ...

Page 15: ...d in and the battery is not fully charged The LED indicator glows continuously Green When the charger is plugged in and the battery has been fully charged The LED indicator lamp on the independent accompanying battery charger Signal Type Explanation The LED indicator glows continuously in red The battery is being charged The LED indicator glows continuously in green The battery is fully charged 3 ...

Page 16: ...era is being charged a prompt window will pop up Battery not detected auto shutdown in 10 seconds and start 10 seconds countdown If plugged battery within 10 seconds the camera will not shutdown 3 1 4 USB interface functions The thermal camera s USB Type C interface to support 3 functions 1 Support MTP connection to computers for reading and quickly transfer data from the TF card 2 Support real ti...

Page 17: ...e screen is off press the power button to wake up the screen 4 In Auto screen off mode the camera can automatically turn off the screen after a certain time of non operation such as 5 10 30 minutes or never off When selecting Never screen off users can only use the power button to turn the screen off and on 5 when the screen is off plugging in the USB cable to a computer or a power adaptor will wa...

Page 18: ...boot from the pop up window 3 3 Adjusting the Infrared Lens Manually Operation Figure For far focus rotate the focus ring clockwise align the LCD facing towards you For near focus rotate the focus ring counterclockwise align the LCD facing towards you ...

Page 19: ...SB port In the file explorer open the Gallery file of the TF card disk and copy desired files to the computer Import the data to the PC software for further analysis and reporting 3 5 Copying the TF card s data to computer Via USB cable After capturing images or videos the files are stored in the TF card The image and video files can be copied to a computer from the TF card via USB cable Operation...

Page 20: ...ing 3 6 The Laser Ranger as a pointer The laser ranger can serve as a laser pointer When turned on a laser dot is visible on the target object 1 To turn on the laser press the laser button 2 When the laser is activated there will be a visible symbol on the top right corner of the screen and the laser dot will be approximately on the center of the screen 3 To turn off the laser release the laser bu...

Page 21: ...terface and gallery s image analysis interface Long press on the AI key 2s to enter the AI programmable interface to link different functions onto the button Press the OK button to finalize the option and press the Return button to abort the selection process Tap on the AI key to activate the linked function Available programmable key functions on the main interface ...

Page 22: ...lette preview Switch scale mode Switch image mode Available programmable key functions on image freeze interface Favorite Voice annotation Text annotation Tag QR tag Available AI programmable key functions on Gallery s image analysis interface ...

Page 23: ...19 Favorite Voice annotation Text annotation Tag QR tag Switch palette Switch scale mode Switch image mode Note On the video analyzing interface the AI programmable key is not available ...

Page 24: ...20 3 8 Gallery Press the Gallery button to get access to the gallery like the image shown below For specific instructions please refer to chapter 8 on the menu ...

Page 25: ...niform Calibration NUC is on proceeding NUC is proceeded automatically for example when the device is starting changing measurement range and every few minutes Manually operate NUC Users can manually operate NUC by long press the gallery button for more than 2 seconds ...

Page 26: ...age room alarm Bluetooth Wi Fi Wi Fi hotspot geographical location and laser on indicator Introduction Battery icon indication of battery s power level and charging status TF card low storage room alarm when the TF card s storage room is lower than 100MB it will be displayed Laser on indicator when the laser is activated the icon will be displayed ...

Page 27: ...cific instructions refer to section 4 8 6 3 Palette and temperature scale display On the right side is the temperature scale displays currently used palette color the upper and lower limits of the temperature scale temperature span For specific instructions please refer to Section 4 5 Temperature Scale Mode and 4 10 Palette 4 LOGO System Date Time On the left bottom side of the screen are the bran...

Page 28: ... distance For specific instructions please refer to section 4 6 Measurement Parameters Settings 4 2 Swipe down menu This menu can be displayed by swiping from up to down on the screen The menu contains system functions like WLAN Bluetooth flashlight Hide overlays SR super resolution volume and brightness 1 To open Swipe down from the top of the screen 2 Button control can be set by click 3 To clos...

Page 29: ... access to functions like gallery browsing focusing and taking images As shown below Display overlay info hide overlay info 4 3 Digital zoom of real time imaging The Real time thermal image and video can be scaled using the digital zoom function of the thermal imager The digital zoom function is only available in thermal image mode Operating Procedures Zoom in Touch the screen with two fingers and...

Page 30: ...digital zoom Gallery image Support for digital zoom 1 Hide the adjusting scroll Pressing the OK or return button When magnification is greater than 1 0 it will display the zoomed value when magnification is 1 0 it will hide the zoomed value 2 The magnifying capability is determined by the device model The minimal magnification increment is 0 1 4 4 System Menu ...

Page 31: ...on 3 Image mode thermal image digital camera image picture in picture thermal digital image fusion mode settings 4 ROI temperature measurement tools points rectangles circles lines etc settings for sound alarm temperature rise delete display settings for temperature measurement masks 5 Palette Iron Grey Rainbow Rain Medical GreyRed etc above the alarm temperature below the alarm temperature the in...

Page 32: ...r display effect according to the histogram of overall temperature distribution On the right side of the screen it displays the temperature scale with the max and min temperature values which are also calculated according to the Histogram 4 5 2 Manual Scale Mode In Manual Scale Mode the upper and lower limits of temperature scale limits can be set manually The manual scale has two span options whi...

Page 33: ...perature scale can be adjusted 1 After selecting the MAX MIN manual temperature scale mode the upper and lower limits of the temperature scale can be selected And the grey icon represents the selected state 2 The upper and lower limits of the temperature scale in the selected state can ...

Page 34: ...ower limits of the temperature scale can be adjusted at the same time by using the slider As shown in the figure below the lower limit of the temperature scale can be adjusted separately by using the slider As shown in the figure below the upper limit of the temperature scale can be adjusted separately by using the slider ...

Page 35: ...re locked and cannot be adjusted Users can adjust the upper or lower limit by pressing the left and right direction keys The selected limit is displayed in gray As shown in the image below the upper limit is selected And the upper limit of temperature scale can be adjusted by up and down ...

Page 36: ... limit is selected And the lower limit of the temperature scale can be adjusted by up and down direction key As shown in the image below the upper and lower limits are selected And the range of temperature scale can be adjusted by up and down direction key ...

Page 37: ... will gradually increase 4 5 2 2 Temperature span mode In temperature span mode the temperature scale span difference between upper and lower limits value can be adjusted independently The upper and lower limits of the temperature scale can only be adjusted at the same time not separately As shown below ...

Page 38: ... at the same time not separately Press the left and right direction keys to adjust the temperature scale range Note aside from touching the screen the scale can also be changed by pressing buttons and scrolling on the screen For more specific instructions please see the manual scale mode 4 6 Measurement Parameter Settings is the temperature parameter set button which can be used to adjust the temp...

Page 39: ...s the rate of the measured object s outward radiation energy to a black body s at the same temperature and wavelength The value is between 0 and 1 0 Note Emissivity is one of the most important parameters for accurate temperature measurement ...

Page 40: ...terial type is not in the material emissivity table or unknown please contact Fotric for professional support 4 Click on other areas of the thermal image screen or click the back button to complete the setting Note For partial emissivity please refer to ROI partial emissivity setting 4 6 2 Setting Reflected Temperature The reflected temperature set compensates for the radiation from the surroundin...

Page 41: ...e back button to complete the settings Note Try to avoid reflection interference if possible It can greatly improve measurement accuracy 4 6 3 Setting Ambient Temperature Ambient temperature is the air temperature between the measured object and the Lens of the thermal imager Available setting range 20 70 Celsius To set the ambient temperature please perform the following procedures 1 Click the am...

Page 42: ...ct and the Lens of the thermal imager Therefore when the measured target is far it is important to set the appropriate value for this parameter To set the relative humidity please perform the following procedures 1 Click the relative humidity set button 2 Slide up and down to set the relative humidity value 3 Click on other areas of the thermal image screen or click the back button to complete set...

Page 43: ...orm the following procedures 1 Click the measure distance set button 2 According to the actual distance between the measured target and the infrared thermal imager lens slide the distance value on the screen up and down and set the distance value to the actual value 3 Click on other areas of the thermal image screen or click the back button to complete the setting 4 6 6 Setting IR Window Compensat...

Page 44: ...sation set button 3 Slide up and down to select the temperature of the external optical window lens 4 Slide up and down 0 01 1 0 and set the transmittance value 5 Click on other areas of the thermal image screen or click the back button to complete IR window compensation setting Note If the selected external optical lens has been calibrated at the factory or there is no external infrared window th...

Page 45: ...image visible light image PIP and image fusion mode Click the icon the submenu for image mode will pop up 4 7 1 Thermal image mode Displays infrared thermal image It is the default mode when turn on the thermal camera When no ROI is added the measurement result bar will display the maximum and minimum temperature of the entire screen and there will be two cursors indicating their position ...

Page 46: ...rature of the entire screen Note under thermal image mode please make sure the image is properly focused If the image is out of focus it will affect both image quality and the accuracy of temperature measurement 4 7 2 Digital camera mode Displays visual light digital camera image Under digital camera mode the following functions are not available Temperature scale Measurement parameters ROI Palett...

Page 47: ...lays Infrared thermal image superimposed on the visual light digital image By default the thermal display area is 1 4 of the entire screen Users can adjust the thermal image areas and position by touch screen as the below following images ...

Page 48: ...l image 3 When specific ROI is selected Resize and reposition mode can alternate by pressing the OK button Pressing the Return button can exit editing mode 4 After reboot the size and position of the PIP window will return to default in the middle and size Note In Picture in Picture Mode please make sure the infrared thermal ...

Page 49: ...rate and the visual light image will not match the thermal image 4 7 4 Image Fusion Mode Thermal Visual light Image Fusion Mode Fusion of thermal image and visual light digital camera image to enhance the display of image visible contrasts In image fusion mode by default a transparency scroll will appear as shown below ...

Page 50: ...g wheel is on screen users can adjust its percentage by swiping on the wheel or pressing the left right direction button Note In image fusion Mode please ensure the accurate focus of the thermal imager If the infrared thermal image is not in focus the temperature measurement may not be accurate and the visual light image will not match the thermal image 4 8 ROI measurement tools Click the ROI meas...

Page 51: ...ine Click to add a movable circle measurement area Click to select the ROIs ROI is the abbreviation for Region of Interest ROI could be rectangle circle line or spot Ci represents circle ROI Ar represents Area Rectangle ROI Li represents line ROI Sp represents spot ROI ROI can be added through touch screen or on button operation To add ROI please follow the instructions below 1 Touch screen operat...

Page 52: ...nter of the screen 4 8 2 ROI Selection Cancel Selection ROI can be selected through touch screen or on button operation To select ROI please follow the instructions below 1 Touch screen operation 1 Click on the spot line s middle two ends rectangle s four corners and center to select the current ROI 2 Clicking on a region outside of the ROI to cancel the selection 2 On Panel operation 1 choose the...

Page 53: ...ng ROI It is possible to move resize ROI and adjust their emissivity if needed Click to select ROI Click to set the sound silent alarm Click to move the ROI position Click to resize the ROI area Click to set ROI partition emissivity Click to delete selected ROI You can move the ROIs by touch screen or On panel operations To move the selected ROIs please follow the procedures as below ...

Page 54: ...l enable continuous movement but the step length will not increase ROI s size is editable by touch screen and On panel operation To move the selected ROIs please follow the procedures as below 1 touch screen operation 1 Following the instruction of 4 8 1 select the desired ROI 2 Press the corner of ROI and drag your finger The ROI s size will change according to your movement Point Do not support ...

Page 55: ...of delete ROI delete the selected one and clear all Delete selected ROI Users can delete ROI by touch screen and On panel operation To delete the selected ROIs please follow the procedures as below 1 Touch screen operation 1 Following the instruction of 4 8 1 select the ROI you want to delete ex Ci1 2 Click the menu button and the deleting ROI icon will appear ...

Page 56: ...ROI has been deleted successfully 2 On panel operation 1 Following the instruction of 4 8 1 select the ROI you want to delete ex Ci1 2 Press the OK button the deleting ROI icon will appear 3 Selecting the Delete icon by pressing the left right direction key then press OK to delete ...

Page 57: ... Touch screen operation 1 Click the system menu button 2 Click the ROI measurement tool button 3 Click the Clear ROI button to clear all ROI information on the screen as the following image indicates 2 On Panel operation 1 Press the OK button the Clear all ROIs icon will appear 2 Select the clear ROIs icon by pressing the left right direction key then press OK to clear all the ROIs on the screen ...

Page 58: ...n cleared successfully 4 8 5 Setting ROI Partial Emissivity ROI Partial Emissivity Set button For the emissivity of material that is not included in the chart you may find it in the emissivity table at the end of this manual ...

Page 59: ...izing page the value ranging from 0 01 to 1 0 On the right side is the emissivity material table 3 Click on the left side to turn it on 4 If the emissivity of the material is known you can set it by scrolling in the middle section of the screen 5 You can also find the matching material by scrolling on the right side of the screen 6 After setting the ROI partial emissivity click on the blank part o...

Page 60: ...lect the right emissivity 5 Use left right direction keys to get to the right lane of the interface then use up down direction keys to select the matching material 6 After setting the ROI partial emissivity press the return key to complete the setting 4 8 6 Setting ROI Display is the ROI display setting button The available options for display are maximum minimum average temperature and emissivity...

Page 61: ...lecting the display options by pressing the up down direction key then press OK to display hide the selected feature After the display setting press on back button on the screen to complete the setting 4 8 7 Temperature Rise Calculation This icon is for temperature rise calculation The temperature rise feature chooses a reference value and all temperature display values on the screen will be the d...

Page 62: ...y values on the screen will be the actual temperature minus the minimum temperature on Ar1 2 Temp rise Calculating temperature difference between all ROIs and a fixed value if you want to lower all temperature display values by 20 you can set the Temp rise value to 20 This function can effectively eliminate environmental interference ...

Page 63: ...n In the middle of the interface you can set the correct target by scrolling 3 If the reference temperature is a constant value users can scroll up and down to adjust the reference temp on the right side of the temp rise interface 4 After ROI temp rise set click on the blank area on the screen to finalize the setting 2 On panel operation 1 Click the OK button then the emissivity button will appear...

Page 64: ...gered the alarm icon is white and not blinking No special color on temperature values No alarm sound High temperature alarm When the detected temperature is higher than the preset high temperature threshold the temperature value will turn red and a sharp rapid beep sound can be set triggered to alert Low temperature alarm When the detected temperature is lower than the preset low temperature thres...

Page 65: ... Open the sound alarm interface left lane displays options Turn off high temperature alarm low temperature alarm On second lane you can choose your interested attribute maximum temperature minimum temperature of the region The third lane displays threshold for triggering alarm The Right lane displays sound effect options for when the alarm is triggered silence buzzing 3 Choose high temperature ala...

Page 66: ...gering alarm Right lane displays sound effect options for when the alarm is triggered silence buzzing 3 Use up down direction keys to select high low temperature alarm in the left lane of the interface 4 Use left right direction keys to switch to the second lane of sound alarm interface and use up down direction keys to select max min temperature of ROI 5 Use left right direction keys to switch to...

Page 67: ...ding the high temperature abnormal area of target object color alarm isotherm below temperature alarm for quickly finding the low temperature abnormal area of the target object color alarm isotherm interval temperature alarm for quickly finding the temperature abnormal area of the target object This button reveals more palette options as shown below ...

Page 68: ...e used for rapid screening of temperature anomalies This thermal imager supports three kinds of isotherms above temperature below temperature and interval in between temperatures color alarm isotherm above temperature alarm for quickly finding the high temperature abnormal area of the target object ...

Page 69: ... palette temperature scale change mode is not available 2 The value in the upper right corner indicates the current alarming threshold The alarm area is adjustable by touching the screen which will turn it blue and by pressing up and down keys The overall image areas display will change according to the dynamic palette on the right side 3 Touch the number icon s value on the top right corner to tu...

Page 70: ... threshold The alarm area is adjustable by touching the screen which will turn it blue and by pressing up and down keys The overall image areas display will change according to the dynamic palette on the right side 3 Touch the number icon s value on the top right corner to turn it blue and press up or lower direction keys to adjust temperature values o Pressing left or right direction keys touchin...

Page 71: ...ing threshold The alarm area is adjustable by touching the screen which will turn it blue and by pressing up and down keys The overall image areas display will change according to the dynamic palette on the right side 3 Touch the number icon s value on the top right corner to turn it blue and press up or lower direction keys to adjust temperature values Pressing left or right direction keys touchi...

Page 72: ...68 4 11 4 System settings The system settings menu includes the following options Capture Mode Connection Temperature Measurement Range Storage Save Options Device Set ...

Page 73: ...69 SYSTEM SETTINGS 5 1 Capture mode The device can be set to take single frame picture record IRS radiometric MP4 videos or time lapse pictures 5 2 Video recording ...

Page 74: ...P4 is a plain video without temperature data 4 In Setting Storage and save options Video format users can alternate between IRS and MP4 files 5 Full radiometric video recording is only available in thermal mode MP4 recording supports all modes Note After the MP4 video is saved it can no longer be edited 5 3 Time lapse mode 1 Users can set intervals between taken photos shortest being 2 seconds and...

Page 75: ...et number of photos has been met Note During time lapse shooting image mode changing is not available and only the thermal image mode is available No operations aside from manual changing focus are available 5 4 Connection In connection set users can set up Wi Fi Hotspot Bluetooth and FTP data transferring 5 4 1 Wi Fi The thermal imager can be connected to WLAN via Wi Fi ...

Page 76: ...hoose an available Wi Fi network Enter password if required 5 4 2 Hotspot 1 Click on the Main interface to display the menu bar 2 Click on settings 3 Click on Connectivity Hotspot 4 Turn on the Hotspot function 5 Enter Hotspot s username and password 6 Hotspot can be used to transfer data from thermal imager to computer via FTP protocols ...

Page 77: ... alarms When paired with Bluetooth the thermal camera s Mic and Speaker will be deactivated 5 4 4 WLAN FTP data transfer When the FTP Transfer function is turned on the thermal camera s storage data TF card can be transferred to a computer via FTP protocols Click on Settings Connection FTP Transfer 1 Connect a computer and thermal cameras to the same WLAN network or ...

Page 78: ...ce and file system without extra validation 4 If anonymous access is turned off the clients must have pre set user name and password to access the file system Note When using FTP Transfer the computer and thermal imager must be connected to the same WLAN Network or via hotspot function 5 5 Setting Temperature Range Settings Temp Range 1 Choose the appropriate temperature range for measurement 2 Th...

Page 79: ...and time lapse mode Video format this setting defines the storage format of videos Available options are IRS file full radiometric files support temp analysis and editing MP4 after the video is saved it can no longer be edited The recorded content would include the user s screen operation Save digital image as separate Thermal image PIP image Fusion image and digital image are saved in one JPEG fi...

Page 80: ...age Fusion mode neither can it capture a digital image Delete all saved files It will pop up prompt asking whether to permanently delete all the files saved in the storage card Users can either confirm or cancel this action 5 7 Device set ...

Page 81: ...77 Under Device set there are the following Options language date region Display settings Location LED lamp as flash Screen off Manual mode Volume Reset USB connect mode About 5 7 1 Language Date Region ...

Page 82: ... this submenu contains settings for language temperature unit distance unit date time and time zone Languages include English traditional Chinese Spanish Korean More will be made available in the future Temperature units K F ...

Page 83: ...79 Distance unit meters feet Date time ...

Page 84: ...80 time zone Date format 5 7 2 TWB ...

Page 85: ...s turned on the overall image color display will be balanced non linearly according to the histogram of overall temperature It makes the extreme hot cold area s color display weaken while other areas are enhanced with more gradients Before TWB After TWB 5 7 3 Display setting Display setting brightness of the screen and image overlay information ...

Page 86: ...82 Slide to change the brightness of the screen The information image overlay contains are all displayed in the images above ...

Page 87: ...n the thermal images 5 7 5 LED lamp as flash The LED lamp on the thermal imager can serve as a flash for the digital camera When this function is turned on the thermal imager will activate an LED flash lamp when capturing images The LED can also be turned on permanently on the Swipe down menu ...

Page 88: ...w long the screen stays on when there is no operation Options are 5 mins 10 mins 30 mins and never When the screen is off pressing the power button can wake it The screen can be turned off manually by pressing the power button 5 7 7 Manual mode settings ...

Page 89: ...mperature of the manual scale range separately or together Temperature span the max and min temperature of the manual scale range can only be adjusted simultaneously and the smallest span is 2 For more information please see Temperature span mode 5 7 8 Volume Swipe to adjust the volume of the device 5 7 9 Reset ...

Page 90: ...TP and USB Charger modes USB MTP The USB interface can be used for data transfer between the camera s SD card and computer Or be used for thermal video streaming Power charging also works in this mode USB Charger The USB interface can be used for power charging only 5 7 11 About ...

Page 91: ...Camera model type Camera serial number Camera software version Camera system version Camera sensor resolution info camera Lens type Battery Level Remaining SD Card storage Capacity Camera Status info IP Address MAC Bluetooth and Systems update function ...

Page 92: ...ge Freeze Interface without saving the image The Image Freeze Interface function in single frame capture of thermal PIP and image fusion modes The Image Freeze Interface function is not available in Visual light digital camera image mode The thermal image s file name will appear on the bottom left corner of the freeze image Click on to display the image analysis menu for freeze image ...

Page 93: ... can be screened by the Favorite button in the gallery Temperature scale set button For details see 4 5 Temperature Scale Mode ROI measurement tool For details see 4 8 ROI Measurement Tool Voice annotation Text annotation Tag 6 1 Favorite ...

Page 94: ...favorite image files 6 2 Voice annotation Click on to enter voice annotation The voice annotation supports 120 seconds of voice recording annotation in the image file It can be played in the gallery or on PC analysis and reporting software Close Play Record Delete When the voice recording is completed close the voice annotation window and a voice icon will appear on the top right corner of the ima...

Page 95: ...91 6 3 Text annotation Click on to enter text annotation Text annotation can be added to the thermal image file by the virtual keyboard on the screen Close ...

Page 96: ...keyboard will pop up 2 After typing the text contents in press the return button to exit the virtual keyboard 3 Click the save button to save the text information in the thermal image And a text annotation icon will appear on the top right corner of the image freeze interface ...

Page 97: ... In the image freeze interface Tag information can be inputted by QR code scanning and virtual keyboard Close QR code scanning Save 6 4 1 Input by the virtual keyboard 1 Click on text input block and a virtual keyboard will appear ...

Page 98: ...ents in press the return button to exit the virtual keyboard and save 3 A tag icon will appear on the top right corner of the screen 6 4 2 QR code scanning 1 Click to display the QR scan interface and aim towards the desired QR code ...

Page 99: ...95 2 After successfully scanned the text content from the QR code will appear in the text input block 3 Click save and the tag icon will appear on the top right corner of the image freeze interface ...

Page 100: ...ave the video Pressing the back button twice on the video freeze interface will exit it without saving the video Image freeze interface only exists in IRS format mode not MP4 format mode In IRS format mode Played time total recording time will appear on the top right corner of the video freeze interface In the video freeze interface click to display the analysis menu ...

Page 101: ...97 Play button Temperature scale setting See 4 5 of this manual ROI measurement tools see 4 8 of this manual Voice annotation see 6 2 of this manual Text annotation see 6 3 of this manual Save button ...

Page 102: ...Click either on the menu or on the center of the screen to play pause resume 7 2 Save 1 Click on the menu to save the radiometric video and exit the video freeze interface 2 Press the trigger button will also save the radiometric video and exit the video freeze interface ...

Page 103: ...e images can be switched by clicking on the direction keys or by touch screen and be selected to analyze or display To return to the live interface click on the Back button In the Gallery interface touch the images to select Filter favorite files Filter tag files File analysis only available for a thermal image or IRS radiometric video View the digital image Play the MP4 video when an MP4 video is...

Page 104: ... contains flies of the thermal image digital image IRS radiometric video MP4 video and time lapse images Time lapse images portray the consecutively taken images as a group When selecting the time lapse group click on it again to enter the group menu which displays all the taken images ...

Page 105: ... 1 Favorite Filter Click on the to filter all the Favorite file Click it again to undo the filter For more information see section 6 1 of this manual 8 2 Tags filter Click to enter the Tags filter interface ...

Page 106: ... once to select and click again to analyze or view play 1 Thermal image PIP fusion images can all be selected and analyzed by clicking the icon or pressing the OK button 2 Digital images can be viewed by clicking the icon or pressing the OK button 3 IRS radiometric videos can be selected and analyzed by clicking the icon or pressing the OK button 4 MP4 files can be viewed by clicking the icon or p...

Page 107: ...103 8 4 Thermal files analysis 8 4 1 Thermal image analysis Thermal images can be reviewed and analyzed Click to display the menu Temperature scale mode see section 4 5 ...

Page 108: ...an switch to thermal image PIP image fusion Favorite see section 6 1 Save More Measurement parameters see section 4 6 Palette see section 4 10 Voice annotation see section 6 2 Text annotation see section 6 3 Tags see section 6 4 Detailed info of the file ...

Page 109: ... not only playable but also analyzable as shown below Play Temperature scale mode see section 4 5 ROI measurement tools see section 4 8 Measurement parameters see section 4 6 Palette see section 4 10 More Voice annotation see section 6 2 Text annotation see section 6 3 Detailed info of the file ...

Page 110: ...deo file 1 Open the gallery by pressing the gallery button 2 All the files are displayed in the gallery grouped by captured date 3 Select an image click the Delete button or press the OK button to display the Delete prompt window ...

Page 111: ...of the files to enter multi selection mode 2 Or click on a certain date to select all the files on that date 3 Click on the selection box on top of the screen to select all files in the gallery 4 Click on Delete and it will display a Delete prompt window 5 Delete imaging files by clicking on Confirm ...

Page 112: ... piece of soft cloth 9 1 3 Cleaning steps Please follow the instructions below 1 Dip the cloth with an appropriate amount of fluid 2 Clean the components with the cloth Note Please don t apply any corrosive liquid onto any part of the thermal imager 9 2 Cleaning lenses 9 2 1 Fluid Please apply the following fluid 1 Commercial lens liquid cleanser containing at least 30 isopropanol ...

Page 113: ... focal plane detector A tiny trace of dust on the IR detector could cause a massive blemish on thermal images If you were to clean the dust off the detector please follow below procedures as below Caution 1 This section is only applicable for thermal imagers with an exposable uncooled infrared focal plane detector 2 Under certain circumstances uncooled infrared focal plane detector surface must be...

Page 114: ...2 Please don t disassembly or squish the batteries 3 If the product is not going to be used for a long time please take out the battery to prevent possible leakage from the battery damaging the product 4 Please only use the FOTRIC authorized power adaptor and charger to charge the batteries 5 Please keep the batteries in a clean and dry environment Note to avoid accidents please do not expose the ...

Page 115: ...emperature unit that is widely accepted globally Under standard atmospheric pressure water s boiling temperature is defined 100 and its melting point is defined 0 32 1 8 or K 273 15 Fahrenheit Fahrenheit is a temperature unit that is widely accepted in North America x 1 8 32 Infrared radiation Infrared radiation is a form of electromagnetic radiation Any object with a temperature above absolute ze...

Page 116: ...nvection and is usually caused by an imbalance of temperature Atmospheric windows A range of wavelengths over which there is relatively little absorption of radiation by atmospheric gases is called atmospheric window The atmospheric window of the infrared band locates between 7 14µm where the atmospheric transmittance is most stable Therefore thermal measurement on this window is particularly accu...

Page 117: ...unit of a detector is called pixel Uncooled Infrared Focal Plane Array FPA In the earlier stage of development FPA detectors require cryogenic cooling and their sizes are massive Nowadays FPA detectors don t necessarily require cooling and can take on high accuracy measurements There are two types of FPA sensors optical readout uncooled focal plane array and electrical readout uncooled focal plane...

Page 118: ...re distribution of an object By receiving the object s radiation energy the thermal imager converts pixels temperature values into visible colors on the matrix coordinates Each pixel represents a temperature measuring point on the object s surface Measurement Range Measurement Range refers to the temperature range that a thermal imager can accurately measure and record Outside of the measuring ran...

Page 119: ...rks every point of the same temperature with the same color in a certain range It aids real time analysis Cold spot and Hot spot The point with the highest temperature in a certain region is called a hot spot Conversely the point with the lowest temperature in a certain region is called a cold spot Emissivity ε Emissivity is a measure of how much radiation is emitted from the object compared to th...

Page 120: ...entage of absolute humidity of air at a certain temperature and saturated vapor pressure of water at the same temperature Specular reflection Specular reflection usually occurs on an object surface of high reflectivity or low emissivity However the occurrence of specular reflection does not guarantee high reflectivity Reflectance ρ It refers to an object s ability to reflect radiant energy It depe...

Page 121: ...vity of a certain wavelength at thermal equilibrium an object s absorptivity of thermal radiation is equal to its emissivity at the same temperature Planck s radiation law Planck s radiation law indicates that energy emitted by a blackbody is dependent on the frequency of the radiation E hf h being the Planck s constant and f being the frequency of the radiation Stefan Boltzmann law The Stefan Bol...

Page 122: ...rought iron Roughened 25 0 94 Polished 38 0 28 Nickel Oxidized 200 0 37 Stainless steel Oxidized 60 0 85 Steel Oxidized at 800 200 0 79 Common brick Surface 20 0 93 Concrete Surface 20 0 92 Glass Polished plate 20 0 94 Lacquer White 100 0 92 Natural color black 100 0 97 Carbon Smoke black 25 0 95 Candle soot 20 0 95 Graphite rough surface 20 0 98 Paint Average of 16 colors 100 0 94 Paper White 20 ...

Page 123: ...ny Disclaimer Equipment described herein may require EU US and UNSC authorization for export purposes Imagery for illustration purposes only Specifications are subject to change without notice FOTRIC INC 2021 All Rights reserved FOTRIC INC ...

Reviews: