Notice!
If computing power becomes short, the highest priority is always the live images and
recordings. This can lead to impairment of the video content analysis. You should therefore
observe the processor load and optimize the encoder settings or the video content analysis
settings as necessary.
1.
Select a VCA profile and enter the required settings.
2.
If necessary, click the Default button to return all settings to their default values.
3.
Click the Save... button to save the profile settings to another file. A new window is
opened, in which you can specify where you want to save the file and what name you
want to save it under.
4.
Click the Load... button to load a saved profile. A new window opens in which you can
select the profile file and specify where to save the file.
VCA configuration
Select one of the profiles here to activate it or edit it.
You can rename the profile.
1.
To rename the file, click the icon to the right of the list field and enter the new profile
name in the field.
2.
Click the icon again. The new profile name is saved.
Preset
Select Off or Test.
Alarm status
The alarm status is displayed here for information purposes. This means you can check the
effects of your settings immediately.
Aggregation times
Use the slider (from 0 (zero) to 20 (0 is the default) to select the aggregation times.
Analysis type
Select the required analysis algorithm. By default, only is available – this offers a
motion detector and essential recognition of tampering.
Notice!
Additional analysis algorithms with comprehensive functions such as IVMD and IVA are
available from Bosch Security Systems Inc.
If you select one of these algorithms, you can set the corresponding parameters here directly.
You can find information on this in the relevant documents on the product CD supplied.
Metadata is always created for a video content analysis, unless this was explicitly excluded.
Depending on the analysis type selected and the relevant configuration, additional information
overlays the video image in the preview window next to the parameter settings. Options are:
, IVA 5.6, IVA 5.6 Flow. With the analysis type, for example, the sensor
fields in which motion is recorded will be marked with rectangles.
Notice!
On the LIVE Functions page, you can also enable additional information overlays for the LIVE
page (see LIVE Functions, page 93).
Motion detector ( only)
For the detector to function, the following conditions must be met:
–
Analysis must be activated.
AUTODOME 7000
Configuration via IP, Advanced Mode | en 115
Bosch Security Systems, Inc.
Operation Manual