ACS 653, ACS 663 Service Manual
SP00D00624
2021-04-08
Robert Bosch GmbH
61
Diagnostics and Testing
PROCEDURE
ERROR/WARNING
DESCRIPTION OF
ERROR/WARNING
Calibrate Load Cells
Calibration failed!
Slope is out of range.
Difference between upper and lower
limits is too great. Select
RETRY
or
ESC
icon
Calibrate Load Cells
Calibration failed!
Verification weight X. XXXYY.
Weight too high or low.
Select
RETRY
or
ESC
icon.
Calibration Check
Calibration failed.
Select
RETRY
icon to return to the
beginning of the calibration check,
or
ESC
icon to return to the service
menu.
Charge
Insufficient vacuum for
charge.
System vacuum too low to draw in
enough refrigerant. Select
AUTO-
MATIC
,
RETRY
or
ESC
icon.
Charge
Insufficient refrigerant
available for charge.
Refrigerant in ISV too low. Select
ESC
icon. May require tank fill.
Charge Leak Test
Leak test failed!
Check for leaks and retest.
Select
ESC
icon.
Drain Oil
Oil drain halted.
Pressure error.
Pressure insufficient to push oil out
of separator. Select
RETRY
or
ESC
icon.
Drain Oil
Oil drain halted. Flow error.
Oil drain timed out. Select
RETRY
or
ESC
icon.
Enter Password
Invalid password!
Password entered is incorrect. Verify
function password is correct. Select
RETRY
or
ESC
icon.
Fast Charge
Charge stalled!
Check connections and
valves. XX.XXXYY of
XX.XXXYY charged.
Check panel valve position and
couplers. Select
RETRY
or
ESC
icon.
Filter Change
Invalid serial number!
Filter serial number must be different
from any other filter serial number
previously installed. Select
RETRY
or
ESC
icon.
Filter Change
Serial number has already
been used.
Filter serial number must be different
from any other filter serial number
previously installed. Select
RETRY
or
ESC
icon.
Helium Leak Test
Transducer error.
For production only. Exit test.
Leak Check
Pressure test failed.
Check for leaks.
Locate and repair any leaks. Select
RETRY
or
ESC
icon.
Leak Check
Vacuum test failed.
Check for leaks.
Locate and repair any leaks. Select
RETRY
or
ESC
icon.
ERROR MESSAGES