![bonitron M3452 Customer Reference Manual Download Page 74](http://html.mh-extra.com/html/bonitron/m3452/m3452_customer-reference-manual_2787112074.webp)
M3452 vR7 EIP/PDP
74
Always consult Bonitron with any questions or concerns surrounding this
topic.
7.1.3.
B
ONITRON
L
INE
R
EGENERATION
M
ODULES
The Bonitron line regens return regenerative energy back onto the AC line
instead of dissipating the energy as heat in a resistor, and are ideal for
applications with high duty cycles, frequent deceleration, or where heat from
a resistor may be an issue. The regenerated energy is returned to the AC line
with near
‐
unity power factor and can be used to power other equipment,
which quickly offsets the slightly higher initial investment of the line regen
solution.