Trouble shooting
BOMAG
111
BMP 8500
Fault codes of remote control
2023
Engine is shut down
Output valve steer-
ing left, Y 238
Although the output is
switched off, voltage is
present
Current path con-
nected to +12V
X3:21
1020
1021
1022
Code
Fault reaction
Description of fault
Possible cause
Terminal
on BLM
Input
code for
diag-
nose
Code
Fault reaction
Description of fault
Possible cause
2500
Engine is stopped, all func-
tions are locked, horn
sounds
Operation of two remote
control system at the same
time
A remote control with cable
and a wireless remote con-
trol are operated at the same
time.
2600
Engine stopped, emergency
stop relay in the control is
switched off, all outputs on
control are switched off
Remote control emergen-
cy stop
Emergency stop on remote
control operated
2601
Engine stopped, emergency
stop relay in the control is
switched off, all outputs on
control are switched off
Fault in data transfer be-
tween remote control
sender and receiver
Battery empty
Radio signal transmission is
disturbed
Distance between sender an
machine too big
2605
*
Engine stopped, emergency
stop relay in the control is
switched off, all outputs on
control are switched off
Receive signal too weak
Radio signal transmission is
disturbed
Distance between sender an
machine too big
2611
Engine is shut down.
CANopen – fault in bus
communication
2612
Engine is shut down.
CANopen – fault in bus
communication
2613
Engine is shut down
CANopen – fault in bus
communication
*
Output of error code 2605 only with software version older than 1.11!
Summary of Contents for BMP 8500
Page 2: ......
Page 7: ...BOMAG 7 BMP 8500 1 Technical Data...
Page 12: ...Technical Data BOMAG 12 BMP 8500...
Page 13: ...BOMAG 13 BMP 8500 2 Safety regulations...
Page 23: ...BOMAG 23 BMP 8500 3 Indicators and Controls...
Page 24: ...Indicators and Controls BOMAG 24 BMP 8500 Fig 10...
Page 31: ...BOMAG 31 BMP 8500 4 Operation...
Page 55: ...BOMAG 55 BMP 8500 5 Maintenance...
Page 64: ...Maintenance BOMAG 64 BMP 8500...
Page 68: ...Every 10 operating hours BOMAG 68 BMP 8500...
Page 76: ...Every 250 operating hours BOMAG 76 BMP 8500...
Page 88: ...Every 3000 operating hours BOMAG 88 BMP 8500...
Page 94: ...As required BOMAG 94 BMP 8500...
Page 95: ...BOMAG 95 BMP 8500 6 Trouble shooting...
Page 126: ...Trouble shooting BOMAG 126 BMP 8500...
Page 127: ......
Page 128: ......