Every 500 operating hours
BOMAG
79
BMP 8500
5.19 Battery service, checking
the main battery switch
!
Danger
Danger of cauterisation ! Danger of explosion!
When working on the battery do not use open
fire, do not smoke!
The battery contains acid. Do not let acid come
in contact with skin or clothes!
Wear protective clothing!
Do not lay any tools on the battery!
For recharging remove the plugs from the bat-
tery to avoid the accumulation of highly explo-
sive gases.
Environment
Dispose of the old batteries environmentally.
i
Note
Maintenance free batteries also need care. Main-
tenance free only means that the fluid level does
not need to be checked. Each battery suffers un-
der self-discharge, which may, in not checked oc-
casionally, even cause damage to the battery as a
result of exhaustive discharge.
The following therefore applies for the service
life:
l
Switch off all consumers.
l
Check open-circuit voltage of the battery at
regular intervals. At least once per month.
Reference values: 12.6 V = fully charged; 12.3 V =
50% discharged.
l
Recharge the battery immediately after an
open-circuit voltage of 12.25 V or less is
reached. Do not perform quick charging.
The open-circuit voltage of the battery occurs ap-
prox. 10 hours after the last charging process or
one hour after the last discharge.
l
After each charging process allow the battery
to rest for one hour before taking it into service.
l
For resting periods of more than one month
you should always disconnect the battery. Do
not forget to perform regular open-circuit volt-
age measurements.
!
Caution
Exhausted batteries (batteries with formation
of sulphate on the plates) are not covered un-
der warranty!
l
Open the maintenance flap and remove the
battery cover.
Fig. 117
l
Clean the outside of the battery (Fig. 117).
l
Clean battery poles and pole clamps and
grease them with pole grease (Vaseline).
l
Check the fastening of the battery.
l
On serviceable batteries check the acid level,
if necessary top up to the filling mark with dis-
tilled water.
Checking the main battery switch
l
Turn the main battery switch to "horizontal"
position and check by voltage measurement
(ignition key test) whether the batteries are
disconnected from the electric system of the
machine.
Summary of Contents for BMP 8500
Page 2: ......
Page 7: ...BOMAG 7 BMP 8500 1 Technical Data...
Page 12: ...Technical Data BOMAG 12 BMP 8500...
Page 13: ...BOMAG 13 BMP 8500 2 Safety regulations...
Page 23: ...BOMAG 23 BMP 8500 3 Indicators and Controls...
Page 24: ...Indicators and Controls BOMAG 24 BMP 8500 Fig 10...
Page 31: ...BOMAG 31 BMP 8500 4 Operation...
Page 55: ...BOMAG 55 BMP 8500 5 Maintenance...
Page 64: ...Maintenance BOMAG 64 BMP 8500...
Page 68: ...Every 10 operating hours BOMAG 68 BMP 8500...
Page 76: ...Every 250 operating hours BOMAG 76 BMP 8500...
Page 88: ...Every 3000 operating hours BOMAG 88 BMP 8500...
Page 94: ...As required BOMAG 94 BMP 8500...
Page 95: ...BOMAG 95 BMP 8500 6 Trouble shooting...
Page 126: ...Trouble shooting BOMAG 126 BMP 8500...
Page 127: ......
Page 128: ......