Trouble shooting
BOMAG
113
BMP 8500
5025
Engine running
No rotary speed
signal from the
generator regulator
Only warning
Generator regulator
defective
Line between regula-
tor and control inter-
rupted
X3:41
-
5031
Machine standing
Engine stops, en-
gine stalled
Lack of fuel
Engine stopped even
though the BLM con-
trol did not submit a
corresponding com-
mand
5040
Output is switched
off, engine stops
Output HW-shut-
down solenoid, Y
13
Too high current flow
out of this output
Output was switched
off!
Excessive current
flow in current path,
probably because of
a defective coil or a
short circuit to
ground
X3:10
-
5041
Output is switched
off, engine stops
Output HW-shut-
down solenoid, Y
13
Short-circuit current
flow out of this output
Output was
switched off!
Short circuit to
ground in the current
path
Lines rubbed
through
Valve defective
X3:10
-
5042
Output is switched
off, engine stops
Output HW-shut-
down solenoid, Y
13
No or too low current
flow out of this output
Wire breakage in
current path
Current path con-
nected to +12V
X3:10
5040
5041
5042
5043
Output is switched
off, engine stops
Output HW-shut-
down solenoid, Y
13
Although the output
is switched off, volt-
age is present
Current path con-
nected to +12V
X3:10
5040
5041
5042
Code
Fault reaction
Description of fault
Possible cause
Terminal
on BLM
Input
code for
diagnose
Summary of Contents for BMP 8500
Page 2: ......
Page 7: ...BOMAG 7 BMP 8500 1 Technical Data...
Page 12: ...Technical Data BOMAG 12 BMP 8500...
Page 13: ...BOMAG 13 BMP 8500 2 Safety regulations...
Page 23: ...BOMAG 23 BMP 8500 3 Indicators and Controls...
Page 24: ...Indicators and Controls BOMAG 24 BMP 8500 Fig 10...
Page 31: ...BOMAG 31 BMP 8500 4 Operation...
Page 55: ...BOMAG 55 BMP 8500 5 Maintenance...
Page 64: ...Maintenance BOMAG 64 BMP 8500...
Page 68: ...Every 10 operating hours BOMAG 68 BMP 8500...
Page 76: ...Every 250 operating hours BOMAG 76 BMP 8500...
Page 88: ...Every 3000 operating hours BOMAG 88 BMP 8500...
Page 94: ...As required BOMAG 94 BMP 8500...
Page 95: ...BOMAG 95 BMP 8500 6 Trouble shooting...
Page 126: ...Trouble shooting BOMAG 126 BMP 8500...
Page 127: ......
Page 128: ......