Trouble shooting
BOMAG
114
BMP 8500
5050
Output is switched
off, engine runs only
with idle speed
Output relay K 114,
engine speed sole-
noid
Too high current flow
out of this output
Output was switched
off!
Excessive current
flow in current path,
probably because of
a defective coil or a
short circuit to
ground
X3:09
-
5051
Output is switched
off, engine runs only
with idle speed
Output relay K 114,
engine speed sole-
noid
Short-circuit current
flow out of this output
Output was switched
off!
Short circuit to
ground in the current
path
Lines rubbed
through
X3:09
-
5052
Output is switched
off, engine runs only
with idle speed
Output HW-shut-
down solenoid, Y
13
No or too low current
flow out of this output
Wire breakage in
current path
Current path con-
nected to +12V
X3:09
5050
5051
5052
5053
Output is switched
off, engine runs only
with idle speed
Output relay K 114,
engine speed sole-
noid
Although the output
is switched off, volt-
age is present
Current path con-
nected to +12V
X3:09
5050
5051
5052
5054
Input AUX – signal
engine solenoid Y
13
Wire breakage in
current path
X3:04
-
5060
Output switched off,
no potential 15 on
machine, control is
working, engine is
stopped or cannot be
started
Output relay K 11,
changeover of po-
tential 15
Too high current flow
out of this output
Output was switched
off!
Excessive current
flow in current path,
probably because of
a defective coil or a
short circuit to
ground
X3:07
-
Code
Fault reaction
Description of fault
Possible cause
Terminal
on BLM
Input
code for
diagnose
Summary of Contents for BMP 8500
Page 2: ......
Page 7: ...BOMAG 7 BMP 8500 1 Technical Data...
Page 12: ...Technical Data BOMAG 12 BMP 8500...
Page 13: ...BOMAG 13 BMP 8500 2 Safety regulations...
Page 23: ...BOMAG 23 BMP 8500 3 Indicators and Controls...
Page 24: ...Indicators and Controls BOMAG 24 BMP 8500 Fig 10...
Page 31: ...BOMAG 31 BMP 8500 4 Operation...
Page 55: ...BOMAG 55 BMP 8500 5 Maintenance...
Page 64: ...Maintenance BOMAG 64 BMP 8500...
Page 68: ...Every 10 operating hours BOMAG 68 BMP 8500...
Page 76: ...Every 250 operating hours BOMAG 76 BMP 8500...
Page 88: ...Every 3000 operating hours BOMAG 88 BMP 8500...
Page 94: ...As required BOMAG 94 BMP 8500...
Page 95: ...BOMAG 95 BMP 8500 6 Trouble shooting...
Page 126: ...Trouble shooting BOMAG 126 BMP 8500...
Page 127: ......
Page 128: ......