Safety regulations
BOMAG
19
BMP 8500
Working on the battery
When working on the battery do not smoke, do not
use open fire!
Do not let acid come in contact with hands or
clothes! When injured by acid flush off with clear
water and seek medical advice.
Metal objects (e.g. tools, rings, watch straps) must
not come in contact with the battery poles – dan-
ger of short circuit and burning!
When recharging non-serviceable batteries re-
move all plugs, to avoid the accumulation of explo-
sive gases.
Observe the applicable instructions when starting
with an auxiliary battery.
Dispose of old batteries according to regulations.
Switch off the charging current before removing
the charging clamps.
Ensure sufficient ventilation, especially if the bat-
tery is to be charged in a closed room.
Working on the fuel system
Do not inhale any fuel fumes.
Avoid open fire, do not smoke, do not spill any fuel.
Catch running out fuel, do not let it seep into the
ground and dispose off environmentally.
Cleaning work
Do not perform cleaning work while the motor is
running.
Do not use gasoline or other easily inflammable
substances for cleaning.
When cleaning with steam cleaning equipment do
not subject electrical parts and insulation material
to the direct jet of water, or cover it beforehand.
l
Do not guide the water jet into the exhaust and
into the air filter.
After maintenance work
After all maintenance work is completed reinstall
all guards and safety installations.
Repair
Mark a defective machine by attaching a warning
tag to the dashboard.
Before starting electric welding work on the ma-
chine, all electrical components must be discon-
nected from the power supply.
Repair work must only be performed by qualified
and authorized persons. Use our repair instruc-
tions for this work.
Exhaust gases are highly dangerous! Always en-
sure an adequate supply of fresh air when starting
in closed rooms!
Test
The safety of compaction equipment must be
checked by a specialist as required in dependence
on the application and the operating conditions,
however at least once every year.
Radio remote control
The machine must only be operated within the
field of vision of the operator.
The radio remote control must only be used by
trained and authorized persons.
The safety features incorporated in the radio re-
mote control must be checked at regular intervals.
A defective radio remote control must no longer be
used.
In case of radio interferences watch the fault code
display and switch to cable remote control, if nec-
essary
The machine will stop when the reach of the radio
remote control is exceeded.
In case of defects the radio remote control must be
immediately taken out of service. The transmitter
must be switched off via the emergency stop func-
tion. The connecting cable must be disconnected
from the machine related socket on the receiver.
The radio remote control must only be repaired by
the manufacturer or specialists authorized by the
manufacturer.
When working on plug connections the machine
battery must be disconnected or the connecting
cable of the receiver pulled off.
All work related with the initial installation of a sys-
tem or with repair work must only be performed by
qualified personnel.
The person performing the work is fully liable for
professional execution of repair and maintenance
work in compliance with the regulations of the
manufacturer.
Warranty on spare parts can only be granted if
these parts were installed in compliance with our
regulations and instructions and by personnel au-
Summary of Contents for BMP 8500
Page 2: ......
Page 7: ...BOMAG 7 BMP 8500 1 Technical Data...
Page 12: ...Technical Data BOMAG 12 BMP 8500...
Page 13: ...BOMAG 13 BMP 8500 2 Safety regulations...
Page 23: ...BOMAG 23 BMP 8500 3 Indicators and Controls...
Page 24: ...Indicators and Controls BOMAG 24 BMP 8500 Fig 10...
Page 31: ...BOMAG 31 BMP 8500 4 Operation...
Page 55: ...BOMAG 55 BMP 8500 5 Maintenance...
Page 64: ...Maintenance BOMAG 64 BMP 8500...
Page 68: ...Every 10 operating hours BOMAG 68 BMP 8500...
Page 76: ...Every 250 operating hours BOMAG 76 BMP 8500...
Page 88: ...Every 3000 operating hours BOMAG 88 BMP 8500...
Page 94: ...As required BOMAG 94 BMP 8500...
Page 95: ...BOMAG 95 BMP 8500 6 Trouble shooting...
Page 126: ...Trouble shooting BOMAG 126 BMP 8500...
Page 127: ......
Page 128: ......