Trouble shooting
BOMAG
106
BMP 8500
6.7
Fault code
Overview
Fault codes of travel functions
Fault code
Function group
1000 - 1999
Travel system
2000 - 2499
Steering
2500 - 2999
Remote controls
5000 - 5499
Diesel engine
7000 - 7499
Input codes for machine parameterization
7500 - 7999
Operating hour meter, load spectrum (input codes)
8000 - 8999
Severe software error
9000 - 9998
External IO nodes, joysticks, data collectors (CAN communication and hardware de-
fects )
9999
Unknown fault, displayed value higher than +/- 10000, automatic output by the BMFSA
Code
Fault reaction
Description of fault
Possible cause
Terminal
on BLM
Input
code for
diag-
nose
1030
Output is switched
off, function
no longer possible
Output valve travel-
ling forward, Y 16
Too high current flow
out of this output Out-
put was switched off!
Excessive current
flow in current path,
probably because of
a defective coil or a
short circuit to
ground
X3:22
-
1031
Output is switched
off, function no long-
er possible
Output valve travel-
ling forward, Y 16
Short-circuit current
flow out of this output
Output was switched
off!
Short circuit to
ground in the current
path
Lines rubbed through
Valve defective
X3:22
-
1032
Output is switched
off, function no long-
er possible
Output valve travel-
ling forward, Y 16
No or too low current
flow out of this output
Wire breakage in cur-
rent path
Current path con-
nected to +12V
X3:22
1030
1031
1032
Summary of Contents for BMP 8500
Page 2: ......
Page 7: ...BOMAG 7 BMP 8500 1 Technical Data...
Page 12: ...Technical Data BOMAG 12 BMP 8500...
Page 13: ...BOMAG 13 BMP 8500 2 Safety regulations...
Page 23: ...BOMAG 23 BMP 8500 3 Indicators and Controls...
Page 24: ...Indicators and Controls BOMAG 24 BMP 8500 Fig 10...
Page 31: ...BOMAG 31 BMP 8500 4 Operation...
Page 55: ...BOMAG 55 BMP 8500 5 Maintenance...
Page 64: ...Maintenance BOMAG 64 BMP 8500...
Page 68: ...Every 10 operating hours BOMAG 68 BMP 8500...
Page 76: ...Every 250 operating hours BOMAG 76 BMP 8500...
Page 88: ...Every 3000 operating hours BOMAG 88 BMP 8500...
Page 94: ...As required BOMAG 94 BMP 8500...
Page 95: ...BOMAG 95 BMP 8500 6 Trouble shooting...
Page 126: ...Trouble shooting BOMAG 126 BMP 8500...
Page 127: ......
Page 128: ......