62
–
press the ‘Enter’ button again.
If the length of the entered PIN-code is equal to the maximum possible, pressing the Enter button
is not required. The maximum possible length of the PIN-code is determined by the
Maximum PIN
Length
Double entry of the PIN-code eliminates a wrong entry.
When trying to replace a user credential, errors may occur. Description of errors is provided in
Table 1.4.4.7.
Table 1.4.4.7
Credential Replacement Errors
Error Description
Error Code
(Indicator No)
The replaced credential does not exist in the memory (not added or deleted)
1
The replaced credential is suspended
2
The replaced credential is presented as a new one
3
The existing credential is presented as a new one
4
Too short PIN code (less than 2 digits)
5
The entered PIN codes do not match
6
Error saving credential
7
If an error occurs while replacing a credential, the indicators ‘14’ and ‘Access’ are turned off.
The panel displays an error code for 3 seconds by turning red a corresponding indicator in the
intermittent mode. For example, if the error code is 2, the indicator ‘2’ will be turned red in the
intermittent mode for 3 seconds.
The display of the error code is accompanied by a long beep.
The error saving credential may occur in case of attempt to replace Administrator or Installers
credentials (use specific menus for that purpose) or due to hardware failures.
After successful replacement or error code indication, the panel returns to the ‘Administrator
Menu’ mode.
If, within 20 seconds after selecting a menu item, the credential is not presented, the panel will
return to the Quiescent mode. Return to the Quiescent mode is accompanied by a short triple beep.
1.4.5.55 The
Replace User Credential by Number
allows replacing a credential without
changing user rights. It may be useful if the credential is compromised.
There is not restriction in type of credential for replacing in other words Touch Memory (iButton)
can be replaced with PIN code and vice versa.
It differs from the Replace User Credential by need to specify a credential system number to
replace it without presenting/entering a credential itself
When the specified menu item is selected, the “15” indicator turns on continuous green, while the
“Access” indicator is off.
To replace a user credential, the following must be done:
–
enter a credential number using buttons ‘1’ ... ‘10’ (button ‘10’ corresponds to number ‘0’);
–
press the Enter button.
The number can be entered in the format of one, two and three characters, for example, ‘7’, ‘07’
and ‘007’ mean a credential with number 7. When entering a credential number of three characters,
pressing the Enter button is not required.