48
1.4.4
Credentials
1.4.4.1
The panel allows using the following types of credentials:
–
-Touch Memory (iButton) electronic keys, operating on the Dallas Touch Memory interface
(iButton);
–
PIN codes (codes, passwords).
1.4.4.2
The number of digits for different PIN codes may be different.
The minimum is 2 digits.
The maximum is defined by the ‘
Maximum PIN Length
‘configuration parameter and can be up
to 12 digits.
1.4.4.3
The device can store in the non-volatile memory a total of up to 128 credentials of the
listed types.
1.4.4.4
Configuration parameters of credentials are shown in Table 1.4.4.
Table 1.4.4.1 Credential Parameters
1.4.4.5
Credentials of the Primary type (tokens / passwords) are intended for local control of
inputs and outputs and allow users, if they have the appropriate rights:
–
arm (switch on) individual inputs;
–
arm (switch on) a group of inputs;
–
disarm inputs (If
Never Disarm
parameter is disabled for this input);
–
disarm a group of inputs (If N
ever Disarm
parameter disabled for these inputs);
–
reset the alarms of the input group;
–
control the outputs (when the c Control by
START / STOP
buttons parameter is enabled for
the corresponding outputs).
Parameter
Function
Values
1
2
3
Credential Type
Defines the purpose of the credential.
It can be either a PIN code or a Touch
Memory key.
Main
Administrator
Installer
Input1
…
Input20
Determine the rights of the main type
credential for arming / disarming, individually
for each input.
Credentials such as Administrator and
Installer cannot have rights to arm / disarm
inputs
Arm
Disarm
Arming/Disarming
No Control
STAR/STOP
Buttons
Defines the rights of credentials of the Main
type to control the outputs using the START
and STOP buttons.
Credentials of the ‘Administrator’ and
‘Installer’ type cannot have the rights to
control the outputs.
Check/Uncheck
Suspended
The credential does not function
Check/Uncheck