45
15
Fire Lamp
Blinking (0.25s On/0.25s Off) if Fire
Blinking (0.25s On/0.75s Off) if Fire Pre-Alarm
Blinking (0.5s On/0.5s Off) if Intrusion Alarm, Flooding
Detected, Lobby Alarm or ARMING FAILED
Blinking (0.25s On/1.75s Off) if Fault
Turn On if all output-interlinked inputs are armed;
Otherwise turn off.
**
16
Alarm Output 2
Turn on if all output-linked inputs are Armed or Disarmed
(but there is no Alarm Intrusion, Panic Alarm, Lobby
Alarm, Flooding Detected, Fire*, Faults, Disarms etc
Othewise turn off.
**
17
Turn On for a Time before
Arming
Turn on for a set period of time if Arming is in process
(Arming Delay);
Otherwise turn off.
Off
18
Turn Off for a Time before
Arming
Turn off for a set period of time if Arming is in process;
Otherwise turn on.
On
19
Turn On for a Time upon
Arming
Turn on for set period of time if any output-interlinked goes
to the Armed status;
Otherwise turn off.
Off
20
Turn Off for a Time upon
Arming
Turn off for set period of time if any output-interlinked goes
to the Armed status;
Otherwise turn on.
On
21
Turn On for a Time
upon Disarming
Turn on for set period of time if any output-interlinked goes
to the Disarmed status;
Otherwise turn off.
Off
22
Turn Off for a Time upon
Disarming
Turn off for set period of time if any output-interlinked goes
to the Disarmed status;
Otherwise turn off.;
Otherwise turn on..
On
23
Turn On for a Time if
Arming Failed
Turn on for set period of time if any output-interlinked goes
to the Arming Failed status;
Otherwise turn off.
Off
24
Turn Off for a Time if
Arming Failed
Turn off for a set period of time, if any output-linked input
goes the Arming Failed status
Otherwise turn On
On
25
Turn On for a Time upon
Auxiliary Alarm
Turn on for a set period of time if Aux Input Activated;
Otherwise turn off.
Off
26
Turn Off for a Time upon
Auxiliary Alarm
Turn off for a set period of time If Aux Input Activated;
Otherwise turn on.
On
27
Turn On upon
Disarming
Turn on if any output-interlinked input is Disarmed;
Otherwise turn off.
Off
28
Turn Off upon
Disarming
Turn off if any output-interlinked input is Disarmed;
Otherwise turn on..
On
29
Turn On upon Arming
Turn on if any output-interlinked input is Armed;
Otherwise turn off.
Off
30
Turn Off upon Arming
Turn off if any output-interlinked input is Armed;
Otherwise turn on..
On
31
Turn On upon Aux
Activation
Turn on if Aux Input Activated;
Otherwise turn off.
Off
32
Turn Off upon Aux
Activation
Turn off if Aux Input Activated;
Otherwise turn on.
On