The program is blocked (inhibited) blocked as long as the conditions for its start are preserved
(corresponding to the states of the inputs associated with this output).
The program can be resumed:
- manually, by pressing the button START button again;
- automatically, after resetting the alarm states of all inputs and the subsequent repeated activation
of at least one input associated with this output (i.e., the repeated occurrence of the program run
condition).
__
1.4.5.36
In the
Local Control
mode, the panel interacts with the network controller in the same
manner as in the
Quiescent
mode.
1.4.5.37
Switching to the Quiescent mode from the Local control mode is performed by the
following way:
–
Manual using the
____
button
–
Automatically after 20 seconds after the last action (button presenting or credential
presenting).
1.4.5.38
The panel can go to the
Centralized Control
mode, if it is connected to the network
controller. This can be done in the following manners:
–
from the PIN Entry mode, after entering the PIN-code (password) which is not enrolled in the non-
volatile memory of the device;
–
from the ‘Quiescent or PIN Entry, after presenting a credential to the reader that is not stored in the
nonvolatile memory of the panel.
Switching to the Centralized Control mode is accompanied by turning off the indicators ‘1’ ... ‘20’, which
emphasizes that at the moment, the panel provides the centralized control of the portion rather than its
own inputs.
1.4.5.39
In Centralized Control mode, the panel:
–
monitors logical states of the inputs;
–
monitors the status of the outputs;
–
controls the outputs depending on the current state of the inputs (locally);
–
monitors the state of the power inputs;
–
monitors the condition of the enclosure;
–
generates events about all changes in the device elements (inputs, outputs, housing and power
inputs);
–
allows arming / disarming partitions under the control of the network controller
–
interacts with the network controller.
1.4.5.40
In the
Centralized Control
mode, the panel monitors all element (inputs, outputs,
power inputs and enclosure) in the same manner as in the
Quiescent
mode.
1.4.5.41
In the Centralized Control mode, the panel arms/disarms partitions as instructed from
the controller.
For the purpose of the centralized control, user credentials are enrolled in the database of the
network controller with the corresponding privileges. For more details, see the User Guide of the network
controller.