19
C
OM
M
IS
ION
ING
S
Function Test
OK
o
Check elevator opens by hydraulic pressure.
OK
o
Check feedback signal indicates elevator closed and latched.
OK
o
Check required bushings are installed before first use
OK
o
Check all bushing segments are of same size and serial number elevator
OK
o
Check if bushings are fixed correctly
OK
o
Check 18° shoulder with gauge P/N 600168 for wear
OK
o
Check all safety / lock wire is present.
OK
o
Check if feedback valve is present.
OK
o
Check elevator closes by hydraulic pressure.
OK
o
Pick up a pipe.
OK
o
Check if elevator opens after giving command “open elevator”