SERVICING
Cont...
If any of the major gas components need to be replaced, such as the pilot or the gas valve, we
recommend replacing the complete gas component assembly. The assembly is designed to be quickly
and easily replaced with minimal inconvenience to the customer. Once replaced, the service technician
can repair the defective assembly safely and comfortably in his shop and with the right tools and test
equipment. We encourage our authorized dealers to keep a few replacement gas component assemblies
at hand for quick servicing.
Replacing Gas Component Assembly
- Disconnect the gas and electricity to the appliance. Let the appliance cool to room temperature.
- Shut off the gas supply to the appliance and disconnect the gas line to the appliance.
- Remove the logs and burner.
- Remove the pedestal base cover and pedestal back.
-
Remove the screws holding the gas component assembly to the appliance firebox bottom.
- Gently remove the assembly through the pedestal back.
- Replacing the assembly is the reverse of the above instructions.
* Check the tray sealing gasket. Replace if damaged.
The light is situated at the top of the door. Replace with the light bulb specified in the replacement parts
list on page 46. To replace the light bulb follow these instructions:
Ensure the stove is completely cooled before you change the bulb. Make sure switch on the
Battery pack / Receiver is in OFF position.
Turning the electric supply off will not prevent unexpected ignition !!
1.
Turn off electric supply
2.
Open the right side panel.
3.
Unhook the door latch.
4.
Swing the door open.
5.
Using a screw driver, remove the two
screws on top of the door
6.
Carefully lift up the top (be careful with
the attached wires)
7.
Remove old bulb by pulling straight out,
to insert new bulb, push straight in.
(Avoid touching glass with bare
hands, hold bulb with clean cloth or
tissue)
8.
Screw top back on, close door securely
with door latch and turn power back on.
REPLACING MAJOR GAS COMPONENTS
REPLACING HALOGEN LIGHT BULB
Summary of Contents for TORINO
Page 6: ...The torino Page 6 APPLIANCE DIMENSIONS ...
Page 25: ...The torino Page 25 WIRING DIAGRAM 120 V AC ...
Page 26: ...The torino Page 26 LIGHTING INSTRUCTIONS Intermittent Pilot ...
Page 28: ...The torino Page 28 HANDHELD THERMOSTAT REMOTE CONTROL operation instructions ...
Page 29: ...The torino Page 29 HANDHELD THERMOSTAT REMOTE CONTROL operation instructions ...
Page 30: ...The torino Page 30 HANDHELD THERMOSTAT REMOTE CONTROL operation instructions ...
Page 37: ...The torino Page 37 FUEL CONVERSION ...
Page 47: ...The torino Page 47 ...
Page 48: ...The torino Page 48 NOTES SERVICE HISTORY DATE CORRECTIVE ACTION INCLUDE REPLACEMENT PARTS ...