The torino
Page 40
FAN REMOVAL AND INSTALLATION
To remove the fan, for maintenance or replacement, is easily accomplished by the fol-
lowing steps:
1. Disconnect electrical power to the appliance.
2. Remove the 4 screws holding the rear pedestal fan bracket to the appliance (Figure
11).
3. Disconnect all wires, be sure to label wires prior to disconnecting to ensure they are
replaced in the correct location.
4. Remove the 4 screws holding the fan to the rear pedestal fan bracket (Figure 12).
5. Installation is the reverse order of the previous steps.
Figure 11
Screws for fastening fan
bracket to pedestal (2 per
side)
Figure 12
Screws for fastening fan to
bracket (4 screws)
WARNING
Electrical Grounding Instructions
This appliance is equipped with a three prong
(grounding)
plug for your protection against shock hazard and
should be plugged directly into a properly
grounded three prong
receptacle . Do not cut or remove the grounding
prong from this plug.
Summary of Contents for TORINO
Page 6: ...The torino Page 6 APPLIANCE DIMENSIONS ...
Page 25: ...The torino Page 25 WIRING DIAGRAM 120 V AC ...
Page 26: ...The torino Page 26 LIGHTING INSTRUCTIONS Intermittent Pilot ...
Page 28: ...The torino Page 28 HANDHELD THERMOSTAT REMOTE CONTROL operation instructions ...
Page 29: ...The torino Page 29 HANDHELD THERMOSTAT REMOTE CONTROL operation instructions ...
Page 30: ...The torino Page 30 HANDHELD THERMOSTAT REMOTE CONTROL operation instructions ...
Page 37: ...The torino Page 37 FUEL CONVERSION ...
Page 47: ...The torino Page 47 ...
Page 48: ...The torino Page 48 NOTES SERVICE HISTORY DATE CORRECTIVE ACTION INCLUDE REPLACEMENT PARTS ...