The torino
Page 42
TROUBLESHOOTING
Please check to make sure the instructions are followed exactly before attempting
trouble shooting of the appliance.
WARNING:
Troubleshooting and servicing of gas and electrical devices of the
appliance should only be conducted by a qualified service technician.
The pilot will not stay lit.
1) Confirm that the Spark electrode and sense electrode wires are
properly connected to the DFC board (See page 24 for terminal lo-
cations)
2) Confirm that the Pilot burner is properly grounded to the DFC board
and stove chassis.
3) Check the power source or the battery pack connections and
condition of batteries.
If the main burner does not
come ON when the manual
switch or remote control is
turned ON.
1) Confirm that the pilot sparks and lights.
2) Confirm that the Spark electrode and sense electrode wires are
properly connected to the DFC board (See page 24 for terminal loca-
tions)
3) If using the remote control check the condition of the batteries.
4) Check if there is gas supply to the appliance
Pilot will not light.
1. When lighting the appliance for the first time after installation or after
servicing, there is air in the gas line. It takes a while for all the air to
purge out of the pilot before gas can reach the pilot and ignite.
Remove the glass door and try lighting the pilot many times to purge
the air.
2. Check to make sure the gas supply to the appliance is turned on and
there is adequate gas supply pressure to the appliance.
3. Check for sparks between the spark electrode and the pilot head
when the unit is turned on. If there are no sparks,
a. Check for broken or poor connection from the sparker to the
electrode.
b. Check for the spark shorting or arcing at other locations.
c. Check for defective sparker.
d. Check for defective spark electrode.
e. Check the power source or the battery pack connections and condi-
tion of batteries.
Summary of Contents for TORINO
Page 6: ...The torino Page 6 APPLIANCE DIMENSIONS ...
Page 25: ...The torino Page 25 WIRING DIAGRAM 120 V AC ...
Page 26: ...The torino Page 26 LIGHTING INSTRUCTIONS Intermittent Pilot ...
Page 28: ...The torino Page 28 HANDHELD THERMOSTAT REMOTE CONTROL operation instructions ...
Page 29: ...The torino Page 29 HANDHELD THERMOSTAT REMOTE CONTROL operation instructions ...
Page 30: ...The torino Page 30 HANDHELD THERMOSTAT REMOTE CONTROL operation instructions ...
Page 37: ...The torino Page 37 FUEL CONVERSION ...
Page 47: ...The torino Page 47 ...
Page 48: ...The torino Page 48 NOTES SERVICE HISTORY DATE CORRECTIVE ACTION INCLUDE REPLACEMENT PARTS ...