SERVICING
Before servicing, read the terms and conditions of the Blaze King warranty at the back of this manual.
Contact the Blaze King authorized dealer which you purchased the appliance from and provide him with
details of the problem and the installation information which the installer filled out at the back of the
manual.
WARNING:
Servicing of this appliance must be conducted by a qualified service technician.
Improper servicing, adjustment or alteration of this appliance may cause property
damage, personal injury or loss of life. All servicing should be conducted with the
appliance cold.
- Remove the pedestal front to gain access to the air shutter screws (there are 2).
- Loosen the primary air shutter wing nuts, found on the firebox bottom
(caution, make sure unit is not
hot as burns may result)
.
- Sliding the shutter levers back increases aeration while sliding the levers forward decreases
aeration.
- Tighten wing nuts.
- Remove the glass door, logs and firebox liner panels.
- Remove the burner.
- Use a 1/2” wrench to unscrew the orifices
- Change the orifices. Do not over tighten.
- Replace all parts in reverse order and properly set the primary air shutters according to the specifications.
- Check for leaks.
ADJUSTING PRIMARY AIR
CHANGING MAIN BURNER ORIFICE
SERVICING UNDER WARRANTY
- The pressure test taps are located on the valve.
- The taps are located in the front.
- Loosen the set screw inside the tap with a 1/8” wide flat screw driver.
- Connect a 1/4” rubber tube to the tap and a pressure gauge.
- Be sure to tighten the set screw inside the tap after you are finish taking pressure readings.
CHECKING INLET AND OUTLET GAS PRESSURE
Summary of Contents for TORINO
Page 6: ...The torino Page 6 APPLIANCE DIMENSIONS ...
Page 25: ...The torino Page 25 WIRING DIAGRAM 120 V AC ...
Page 26: ...The torino Page 26 LIGHTING INSTRUCTIONS Intermittent Pilot ...
Page 28: ...The torino Page 28 HANDHELD THERMOSTAT REMOTE CONTROL operation instructions ...
Page 29: ...The torino Page 29 HANDHELD THERMOSTAT REMOTE CONTROL operation instructions ...
Page 30: ...The torino Page 30 HANDHELD THERMOSTAT REMOTE CONTROL operation instructions ...
Page 37: ...The torino Page 37 FUEL CONVERSION ...
Page 47: ...The torino Page 47 ...
Page 48: ...The torino Page 48 NOTES SERVICE HISTORY DATE CORRECTIVE ACTION INCLUDE REPLACEMENT PARTS ...