The torino
Page 20
SIMPSON DURAVENT GS SYSTEM PARTS LIST
Description
Part #
Horizontal Termination Kit - In Canada—Mandatory to add a wall thimble.
971
Vertical Termination Kit
978
6” Pipe Length -Black
908B
9” Pipe Length-Black
907B
12” Pipe Length-Black
906B
12” Pipe Length-Galvanized
906
24” Pipe Length-Black
904B
24” Pipe Length-Galvanized
904
36” Pipe Length-Black
903B
36” Pipe Length-Galvanized
903
48” Pipe Length-Black
902B
48” Pipe Length-Galvanized
902
11”- 14 5/8” Adjustable Pipe Length-Black
911B
17”- 24” Adjustable Pipe Length-Black
917B
45° Elbow-Black
945B
45° Elbow-Galvanized
945
45° Elbow-Swivel-Black
945BG
45° Elbow-Swivel-Galvanized
945G
90° Elbow-Galvanized
990
90° Elbow-Black
990B
90° Elbow-Swivel-Galvanized
990G
90° Elbow-Swivel-Black
990GB
Vertical High Wind Termination Cap (must be used for all vertical terminations)
991
Horizontal. DV Termination with 1” return
984GL
Horizontal. Square Termination Cap
984
Horizontal. Square High Wind Termination Cap
985
Snorkel-36” Rise Termination Cap
981
Wall Thimble Cover—Support Box
940
Cathedral Ceiling Support Box
941
Brass Trim fro Ceiling Support Box
3951
Firestop Spacer
963
Flashing 0/12-6/12
943
Flashing 7/12-12/12
943S
Storm Collar
953
Vinyl Siding Standoff
950
Wall Strap
988
Wall Pen Heat Shield (Wall Thimble)
942
SIMPSON DURAVENT DIRECTVENT PRO / GS SYSTEM PARTS LIST
Description
Part #
Old Part #
Horizontal Termination Kit - In Canada—Mandatory to add a wall thimble
(46DVA-KHC.)
46DVA-KHA
971
Vertical Termination Kit
-
978
6” Pipe Length -Black
46DVA-06B
908B
6” Pipe Length –Galvanized
46DVA-06
908
8,5” Black Extension (3”-7”)
46DVA-08AB
-
8,5” Galvanized Extension (3”-7”)
46DVA-08A
-
9” Pipe Length-Black
46DVA-09B
907B
9” Pipe Length-Galvanized
46DVA-09
907
12” Pipe Length-Black
46DVA-12B
906B
12” Pipe Length-Galvanized
46DVA-12
906
16” Black Extension (3”-14.5”)
46DVA-16AB
-
16” Galvanized Extension (3”-14.5”)
46DVA-16A
-
24” Pipe Length-Black
46DVA-24B
904B
24” Pipe Length-Galvanized
46DVA-24
904
36” Pipe Length-Black
46DVA-36B
903B
36” Pipe Length-Galvanized
46DVA-36
903
48” Pipe Length-Black
46DVA-48B
902B
48” Pipe Length-Galvanized
46DVA-48
902
11”- 14 5/8” Adjustable Pipe Length-Black
-
911B
17”- 24” Adjustable Pipe Length-Black
-
917B
45° Elbow-Black
46DVA-E45B
945B, 945BG
45° Elbow-Galvanized
46DVA-E45
945, 945G
90° Elbow-Galvanized
46DVA-E90
990, 990G
90° Elbow-Black
46DVA-E90B
990B, 990BG
Vertical High Wind Termination Cap (must be used for all vertical termina-
tions)
46 DVA-VCH
991
Horizontal. DV Termination with 1” return
-
984GL
Horizontal. Square Termination Cap
-
984
Horizontal. Square High Wind Termination Cap
46DVA-HC
985
Horizontal round termination cap
46DVA-HRCS -
Sconce Termination Cap
46DVA-HSC
-
Wall Thimble Cover—Support Box
46DVA-DC
940
Cathedral Ceiling Support Box
46DVA-CS
941
Brass Trim fro Ceiling Support Box
-
3951
Firestop Spacer
46DVA-FS
963
Flashing 0/12-6/12
46DVA-F6
943
Flashing 7/12-12/12
46DVA-F12
943S
Storm Collar
46DVA-SC
953
Vinyl Siding Standoff
46DVA-VSS
950
Wall Strap
46DVA-WS
988
Wall Pen Heat Shield (Wall Thimble)
46DVA-WT
942
Summary of Contents for TORINO
Page 6: ...The torino Page 6 APPLIANCE DIMENSIONS ...
Page 25: ...The torino Page 25 WIRING DIAGRAM 120 V AC ...
Page 26: ...The torino Page 26 LIGHTING INSTRUCTIONS Intermittent Pilot ...
Page 28: ...The torino Page 28 HANDHELD THERMOSTAT REMOTE CONTROL operation instructions ...
Page 29: ...The torino Page 29 HANDHELD THERMOSTAT REMOTE CONTROL operation instructions ...
Page 30: ...The torino Page 30 HANDHELD THERMOSTAT REMOTE CONTROL operation instructions ...
Page 37: ...The torino Page 37 FUEL CONVERSION ...
Page 47: ...The torino Page 47 ...
Page 48: ...The torino Page 48 NOTES SERVICE HISTORY DATE CORRECTIVE ACTION INCLUDE REPLACEMENT PARTS ...