41
TX/CX 4000
COMMAND 78: INPUT STOP
Selects the number of stop bits of a data stream received at the serial-in port.
A new setting will not be effective immediately: To activate the new setting,
cycle power on the TX/CX 4000.
VALUE
DESCRIPTION
*1
1 Bit
2
2 Bits
Example:
&%Z78,2 sets the number of Stop Bits to 2.
COMMAND 79: INPUT PARITY
Selects the parity of a data stream received at the serial-in port. A new setting
will not be effective immediately: To activate the new setting, cycle power on
the TX/CX 4000.
VALUE
DESCRIPTION
*0
None
1 Odd
2
Even
Example:
&%Z79,2 sets the parity to even.