2
3
CONGRATULATIONS
By choosing a Bionaire
®
humidifier, you have chosen
one of the finest humidifiers on the market today
READ AND RETAIN THE FOLLOWING
FOR FUTURE REFERENCE.
Note:
Carefully remove all securing tapes and
two Water Filters. Keep all packaging for future
storage when humidifier is not in use.
GENERAL DESCRIPTION (SEE FIG. 1)
A
Mist Nozzle
B
Mist Channel
C
Viewing panel
D
Airflow outlet
E
Water tank support (2)
F
Control panel
F1
Power On/Off
F2
Mist Control / Humidity Level Control
G
Base
H
Transducer (not visible)
I
Water basin
J
Water level security switch
K
Security switch
L
Water outlet
M Water Tanks (2)
N
Handle
O
Filter (2)
IMPORTANT SAFEGUARDS
Please read this manual carefully before using
this appliance, as correct use will give you the
best possible performance.
When using electrical appliances, basic safety
precautions should always be followed, including
the following:
•
Read all instructions before using.
•
Close supervision is necessary when any
appliance is used near children. Appliance
must be kept out of the reach of children.
•
Appliance must be used by a responsible adult.
•
Unplug from outlet when not in use, before
putting on or taking off parts, and before cleaning.
•
Do not operate any appliance with a
damaged cord or plug, or after the appliance
malfunctions or has been dropped or damaged
in any manner. If the cord is damaged, it
must be replaced by the the manufacturer or
a service agent in order to avoid hazard.
•
The use of accessory attachments not
recommended or sold by Bionaire
®
may
result in fire, electric shock or personal injury.
•
Do not use outdoors.
•
Do not let cord hang over edge of table or
counter, or touch hot surface including the stove.
•
Do not use appliance for other than intended use.
•
Always disconnect the appliance from the
supply if it is left unattended and before
assembling, disassembling or cleaning.
•
In the event of a momentary electrical
disturbance, the product may malfunction
and require user to reset the product.
•
Check the operating voltage shown on the
back of the unit. Do not operate at higher
voltage than shown.
•
Never turn on, plug in or unplug the
humidifier while your hands are wet in order
to avoid electric shock.
•
Ensure humidifier is level. If the humidifier is not
level always turn the power off before handling it.
•
Do not disassemble the humidifier while it is
plugged in to avoid electric shocks.
•
If you need to replace the plug or cable always
refer to the instructions "Installation of a plug".
•
If the supply cord is damaged, it must be
replaced by the manufacturer or its service
agent or a similarly qualified person.
•
Do not place humidifier in front of ventilating
outlets and keep away from furniture and
other electrical appliances.
•
Do not add water directly into the mist
conductor or nozzle.
ASSEMBLY INSTRUCTIONS
1. Be sure the humidifier is switched off and
disconnected from the wall outlet.
2. Installl the Water Filters into the base.
WARNING:
When installing a new Water
Filter, be sure to first remove the plastic bag,
then follow "Filter Use instructions".
IMPORTANT:
To eliminate the emission of
minerals from the water, it is recommended
that the Water Filter be used.
3. Position Mist Channel (B) over Base (G),
carefully locate into base, (see Fig 2).
4. Insert the Mist Nozzle (A) onto the Mist
channel (B), (see Fig. 2).
5. Place the water tanks on the base (see Fig. 3).
IMPORTANT:
Make sure the water tanks as
well as the water basin are clean before using
the appliance and after storing for a long time.
6. Ensure humidifier is level. If the humidifier is not
level always turn the power off before handling it.
OPERATING INSTRUCTIONS
Fill Water Tanks
NOTE:
Be sure the humidifier is switched off
and disconnected from the wall outlet. The water
you put into the water tanks should be clean and not
U.K. and IRELAND
be over 40° C. (cold boiled water or demineralised
water are recommended).
1. Remove the water tanks out from the base.
2. Unscrew the water outlet valve (L).
3. Fill the tanks with clean water and screw the
valve back tightly onto the tanks. (See Fig. 4)
4. Put the water tanks back on the base. (see Fig.4).
Switch the Unit On and Off (See Fig. 1 F1)
1. Put the plug into the main supply.
2. Press Power ( ) (F1) to switch on and off
the Ultrasonic Humidifier. The LED screen is
lightened when the power is on.
NOTE:
This unit has a memory. The control
panel will remember the previous mist output
level setting after the unit has been turned off.
However, if the unit is unplugged, the control
panel will reset to Hi (II) and will no longer
remember the previous mist output level setting.
Mist Control/ Humidity Level Control (See
Fig. 1 F2)
To raise or lower the humidity level, adjust the
fan to low or high mist output levels:
I / Lo
= Low mist output
II / HI
= High mist output
NOTE: Mist output level setting alternates Hi(II)
to Lo(I) with one touch to the Mist Control (F2)
on the Control Panel (F).
Control Panel
The control panel has a humidity indicator light
and will show differing colours as follows:
Amber
= Low humidity. (Below 50%
Relative Humidity Level)
Green
= Comfort Humidity Level (About
50% Relative Humidity Level)
Blue = High
humidity. (Above
50%
Relative Humidity Level)
Screen flickers
= water level in basin is low,
refill tanks
NOTE:
The recommended humidity level is
between 40% - 50%.
AUTO SAFETY SHUT OFF
This Ultrasonic Humidifier has two built in safety
devices:
1. When the water level in the basin is low, the
transducer will automatically shut off. Refill
the tanks as instructed in "Operating
Instructions" to operate the humidifier again.
2. When the Mist Channel is not positioned correctly
on the base, the fan and Transducer will
automatically shut off and the Control Panel
screen will flicker. Remove and replace the
Mist Channel to ensure proper fit.
FILTER USE
The Water filters are used to retain minerals in
your water and to provide clean moisture. The
filter life is determined by the average daily use
of your humidifier and the water hardness in
your area. The harder the water, the greater the
amount of minerals in the water and more often
you will need to replace the filter. It is strongly
recommended that each filter is replaced every 2
months, (depending on use), or when white dust
is emitted from the unit.
1. Make sure the unit is turned off and
disconnect from the mains outlet. Remove
Water Tanks (M) and Mist Channel (B).
2. If replacing, remove the Filters (O) from the
base and dispose.
3. Remove the protective plastic bag from the new
filters. Soak filters thoroughly by immersing filters
in water for 5 minutes. Install the filters into
the base.
4. Fill the water tanks with clean, cool tap water and
replace it in the base. Wait 15 minutes for water to
pass through the filters before turning on the unit.
The 15 minute wait is necessary to ensure that
the filters are properly saturated and the water is
at its optimal level for best performance.
CARE AND CLEANING
Humidifiers provide comfort by adding moisture
to dry, heated indoor air. To get the most benefit
from the humidifier and to avoid product misuse,
follow all instructions carefully, specifically the
operation, care and maintenance guidelines.
Please note this is an electrical appliance and
requires attention when in use.
Cleaning your humidifier every one or two weeks,
depending on the water conditions is important
in order to maintain efficient, healthy, odour-free
operation. Water quality varies widely and,
combined with build-up of mineral scale in your
humidifier, may under certain conditions promote
the growth of micro-organisms in the water tank.
Before cleaning, Please note the following:
•
DO NOT use soap, detergents, abrasives,
gasoline, glass or furniture polish, or boiling water
to clean any part of your Ultrasonic Humidifier.
These will interfere with the proper operation
of your unit and may affect its appearance.
•
DO NOT use sharp or metal objects to clean
mineral deposits in the reservoir. Contact with
sharp objects can result in damage to the plastic.
•
Mineral deposits should be soaked for up to
20 minutes in plain vinegar and water to
help with their removal.
•
DO NOT clean any part of your humidifier in
the dishwasher.
Daily maintenance:
1. Before cleaning, switch off the unit and unplug
the unit from the electrical outlet.
BU4000I05M1 V.qxd 4/9/05 14:11 Page 7