Chapter 3 Basic Operation
User Manual of Veterinary Monitor
--29--
Attention
Alterations in date and time may lead to animal data and events data lost.
3.9.5 Audio Setup
Alarm Volume
Select the [Audio Setup] Shortcut key, or [Main Menu] – [Alarm Setup] – [Global] to set [Alarm volume]: X
– 10. X is the minimal volume (it depends on the preset minimal sound volume in the alarm configuration),
and 10 is the maximum sound volume.
Key Set Sound Volume
Select the [Audio Setup] shortcut key, or [Main Menu] – [System] – [Screen Setup], or press the screen to
enter the screen setup interface. Select [Key Volume]: 0
~
10. Select 0 to turn-off the volume, and select
10 to turn up the volume to the maximum.
Pulse Sound Volume
Select the [Audio Setup] shortcut key, or [Main Menu] – [Parameters] – [SpO
2
Setup] – [Pulse Volume]: 0 –
10. Select 0 to turn-off the volume, and select 10 to turn it up to the maximum.
Key Set Tone
Select the [Audio Setup] Shortcut key to set the [Key Volume]: Default, Tone 1, Tone 2, and Tone 3.
QRS Prompt Sound Volume
The QRS prompt sound volume is decided by the menu [Alm Source] in [ECG Setup] or [SpO
2
Setup]. When
a parameter in [Alm Source] is set up, the QRS prompt sound volume will sound according to the rhythm of
that parameter. During SpO
2
monitoring, the system also adjust the QRS pulse sound frequency according to
SpO
2
.
Select the [Audio Setup] shortcut key, and then select [Pulse Volume]: 0 – 10, or select [Main Menu] –
[Parameters] – [ECG Setup] – [Others>>] – [QRS Volume]: 0 – 10. Select 0 to turn-off the volume, and 10
to turn it up to the maximum.
3.9.6 Help Menu
Select [Main Menu] – [System] – [Screen Setup] – [Screen Config] – [Menu Help]: On/Off. If On is selected, an
explanation dialogue will be displayed; below the menu if off is selected, explanation will not be displayed.
3.10 Configuration Management
3.10.1 Recent Configuration Self-recovery
The monitor carries out real-time configuration storage, which is the most recent configuration. When the device
is off time does not exceed the user settings restore recently configuration time, after starting the apparatus
automatically recover recently configuration.
Warning
Accidental power failure may lead to the loss of settings.
3.10.2 Turning-on Default Configuration Setup
When the device is off time exceeds the user settings restore recently configuration time, after starting the
apparatus will restore the configuration selected by a user.
Summary of Contents for iM 12
Page 2: ......
Page 12: ...Content VIII User Manual of Veterinary Monitor The Blank Page ...
Page 14: ...Preface 2 User Manual of Veterinary Monitor The Blank Page ...
Page 22: ...Chapter 1 Operation Safety Information 10 User Manual of Veterinary Monitor The Blank Page ...
Page 44: ...Chapter 3 Basic Operation 32 User Manual of Veterinary Monitor The Blank Page ...
Page 54: ...Chapter 5 User Interface 42 User Manual of Veterinary Monitor The Blank Page ...
Page 134: ...Chapter 8 Freeze and Review 122 User Manual of Veterinary Monitor The Blank Page ...
Page 142: ...Chapter 10 Recording 130 User Manual of Veterinary Monitor The Blank Page ...
Page 154: ...Chapter 14 Maintenance 142 User Manual of Veterinary Monitor The Blank Page ...
Page 180: ...Appendix C Alarm Information 168 User Manual of Veterinary Monitor The Blank Page ...
Page 195: ......