DD1050
field:
W1 extension feedback delay (N° of conversions) (NCAM1EST).
Category: Common parameters (FEATURES).
> W1 field feedback occurs after n conversions.
Default Value: [0]; Type: Short
field:
Capacity (MAX).
Category: Common parameters (FEATURES).
> Maximum weighing capacity.
Default Value: [20000]; Type: Decimal
field:
Unit of Measurement (UNITM).
Category: Common parameters (FEATURES).
> The terminal will not convert the unit of measurement when a different unit of measurement
from the set one is selected. In this case, the scale must be re-calibrated with sample weights
of the required unit of measurement.
Default Value: [kg]
•
(kg)
•
(g)
•
(t)
•
(lb)
•
(oz)
field:
Division (DD).
Category: Common parameters (FEATURES).
> Minimum division value given in the selected unit of measurement. Selection of these values
also takes the number of decimals displayed into account. Indicates the division of the last
field in the case of MD or ME instruments.
Default Value: [20]
•
(0.001)
•
(0.002)
•
(0.005)
•
(0.010)
•
(0.020)
•
(0.050)
•
(0.01)
•
(0.02)
•
(0.05)
•
(0.1)
•
(0.2)
•
(0.5)
•
(1)
•
(2)
•
(5)
•
(10)
•
(20)
•
(50)
•
(100)
•
(200)